OVERALL FREQUENCY RESPONSE
1.Insert the a Normal
blank test tape (QZZCRA)
and set
the unit to the Record Pause mode.
2.Apply a reference input signal (1 kHz, -24 dB) through
an attenuator.
3.Attenuate the signal by 20 dB and adjust the frequency
from 50 Hz ~ 10.0kHz.
4.Record the frequency sweep.
5.Playback the recorded signal and assure that it is within
the range shown in Fig.8 in comparison to the reference
frequency (1 kHz).
6.If it is not within the standard range, adjust VR301 (L-CH)
and VR302 (R-CH) so that the frequency level is within
the standard range.
7.Repeat steps 2 ~ 6 above using the CrOz tape(QZZCRX)
and the Metal tape(QZZCRZ)
increasing the frequency
range to 12.5kHz (60Hz2~12.5kHz).
8.Assure that the level is within the range shown in Fig.9.