Wiring Diagram - Ferroli BLUEHELIX THETA C Manual

Table of Contents

Advertisement

Available languages

Available languages

4.6 Wiring diagram

16 Fan
32 Heating circulating pump
34 Heating temperature sensor
42 DHW temperature probe
44 Gas valve
72 Room thermostat (not supplied)
81 Ionization/ignition electrode
95 Diverter valve
44
X04-8
X04-9
230V
X04-1
50Hz
GROUND
95
X04-5
X04-6
X04-7
288
16
X01-3
X01-4
X01-5
X01-6
X01-7
Attention: Remove the jumper on the terminal block before connecting the room thermo-
A
stat or the remote timer control.
To connect multiple zones of the plumbing system controlled by thermostats with voltage-
free contact and there is a need to use the timer control as a function of remote boiler con-
trols, it is necessary to connect the voltage-free contacts of the zones to terminals 1-2 and
the timer control to terminals 5-6.
ALL CONNECTIONS TO THE TERMINAL BLOCK MUST BE WITH VOLTAGE-FREE
CONTACTS (NOT 230V).
96
32
136
X08-13
X08-14
X08-12
X05
8
1
9
X07
X11
LC32
fig. 46- Wiring diagram
cod. 3540000272 - Rev. 01 - 01/2024
BLUEHELIX THETA C
114 Water pressure switch
136 Flowmeter
138 External probe (optional)
139 Remote timer control (optional)
186 Return sensor
191 Fume temperature sensor
288 Frost protection kit
A
ON/OFF switch (configurable)
191
42
186
1
14
1
5
1
X08
X09
34
114
X16
N
L
138
A
5
6
81
72
139
EN