ELECTRICAL CONNECTION DETAILS
OBSERVE ALL GOVERNING CODES AND ORDINANCES
Rating Plate located to the right of the loading port.
• Connect this dryer to a circuit corresponding to that
indicated on Rating Plate and protected by fuses or a
circuit breaker in accordance with local codes.
• Use a power supply cord kit marked for use with
supply cord kit marked for use with clothes dryers.
DO NOT USE EXTENSION CORD WITH THIS
APPLIANCE
• Connect supply wire leads to terminal block as shown
on sketch below, depending on type of installation.
• Make sure screws on terminal block are tight.
FOR THREE-WIRE SUPPLY
(208V & 240V MODELS)
• Remove terminal block cover.
of terminal block.
• Connect Neutral line to center
White Neutral Wire
Green
Ground
Screw
Ground
Strap
Hot Wire
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
• Properly strain relief the cordset or cable to the cable
entry hole with UL recognized strain relief.
• Replace terminal block cover.
GROUNDING INSTRUCTIONS
POWER SUPPLY
AWG MINIMUM
Hot Wire
COPPER
CONDUCTORS
WITH TYPE UL
RECOGNIZED
MINIMUM RATED
OPERATION
3 WIRE RECEPTACLE
(10-30R)
Typical 30 amp receptacle for use where
local codes permit use of flexible type
power supply cord (pigtail).
This appliance must be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electrical current.
Improper connection of the equipment
WARNING
grounding conductor can result in a risk
serviceman if you are in doubt as to whether the appliance
is properly grounded.
Appliance grounded to neutral conductor
WARNING
through a link. If used in a mobile home,
a new construction, a recreational vehicle or if local codes do
cable assembly for use with clothes dryers must be used with
UL recognized strain relief. See manufacturer's instructions.
FOR FOUR-WIRE SUPPLY
(208V & 240V MODELS)
• Remove terminal block cover.
grounding screw in place.
of terminal block.
• Attach ground wire of power
supply to green grounding screw
beside terminal block.
Green or Yellow
Green Grounding Screw
Hot
Wire
Hot
Wire
White Neutral Wire
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
• Properly strain relief the cordset or cable to the cable
entry hole with UL recognized strain relief.
• Replace terminal block cover.
X
G
W
Y
4-WIRE RECEPTACLE (14-30R)
Typical 30 amp receptacle for use
where local codes permit use of
flexible type power supply cord (pigtail).
POWER SUPPLY
MINIMUM COPPER
Ground Wire
LOOP TERMINALS
TYPE UL RECOGNIZED
REMOVE GROUND STRAP
4-CONDUCTOR CORD
ASSEMBLY (Type ST Cable)
Typical 30 amp cord assembly for
use where local codes do not
permit grounding through neutral.