4. (Declination Adjustment)Leaving
it in the playback
position, put the back tension to O and make certain the
erasehead part and supply pinch roller guide part do not
shift, If there is a shift, turn the screw
@ and change the
declination. Looking at it using the mirror cassette , if the
tape shifts up, tighten the screw, and if it shifts down,
loosen the screw.
5. Repeat the adjustments beginning with step 2 and fine
adjust the height and declination. And make sure the tape
does not curl up on the pinch roller guide or the guide
part of the record/playback head.
6. (Depth Adjustment)In order to make the entire head
play the tape smoothly, and to make sure the depth of the
erasehead is neither too shallow nor too deep, loosen
screw @ a bit.
About
0.5 mm
eee
Pe eel
ar ae ay we
Erasehead —~
Normal
Record/ playback
Not deep enough
Too deep
1. Check to make sure that there are no curls or shifts
throughout the whole tape path and that the tape runs
smoothly.
2. Reapply the locking compound to the adjusted screws.
(The locking compound should only be applied to screw
@ after the azimuth has been adjusted.)
Adjustment
Position:
As
seen
from
the
cassette,
side (top) and MD as seen head
on (bottom).
Pinch Roller Pressing Force Measurement
Mode: playback
Hook needle of the tension gauge to the pinch roller shaft
and push back pinch roller to detach it from capstan .
Then, return it gradually to capstan and read the gauge
when the pinch roller begins turning.
Standard Limits:
Tape-up side: 270 — 350 g(9.5 — 120z)
Supply side: 180 — 280g(6.4 — 9.90z)
capstan
pinch
roller
tension
gauge
Torque Adjustment and Measurement
1. Insert a tape for torque measurement, CQ-102C, and put
the set to PLAY mode. Adjust RV801 so that the reading
of the torque meter is 40 + 5g.cm.
2. After the adjustment, measure the back—tension and the
FF/REW torque and check that the following specifi-
cations are satisfied.
CQ102C
| 30 -60g*em (0.42—-0.830z+inch)
FWD
Back tension
FF/REW
CQ-201B
65 —90g+cm (0.90 —1.250z+inch)
CQ-102C
=| 7—11g-cm (0.09 +0.0150z+inch)
3-2. ELECTRICAL ADJUSTMENTS
Note: The adjustment should be performed in the order
given in this service manual.
The adjustment should be performed for both L-CH
and R~CH.
@ Simultaneous REC/PB Mode:
Input the signals to LINE IN terminal and set to REC
mode. Set the monitor switch to TAPE, and. monitor the
recorded signal from LINE OUT terminal.
e Switch Position:
DOLBY
NR
Ooo eee eeeeerereeneseerenssoeesenesnese OFF
ee
TIMER crrvecsreestertetscstceecsssessseoesoonsssens OFF
Ser"
MONITOR
oer eee ee ree reerer er ee eer errr eer eee ee
TAPE
\
2
HX PRO crvrserrecceseceeeesesceesersertecenneseees OFF
CALIBRATION
eee
ee eeee eee ee eee eee erer er eres) OFF
Supply pinch
Takeup pinch
CD DIRECT sos hes paisieeinciisiosseteess OFF
roller
Erasehead
Record/playback
roller
BIA
Sscectnahitneararg) CENTER CLICK
ieee
REC LEVEL *sss--+00 CENTER CLICK