Needle Bar Vibrating Bracket - Singer 250 Series Service Manual

Table of Contents

Advertisement

Needle Bar Vibrating
Removal:
1)
Remove
1111
.
D
and
115)1
.
Bracket
2) Unhook spring A and remove same
.
3)
Loosen screw
B.
4) Loosen screw C
.
5) Remove collar D downwards
.
6)
Loosen
screw
E.
7) Remove eccentric hinge pin F upwards.
8) Remove needle
bar
vibrating
bracket
G
.
If it is necessary to disassemble the unit:
1) Loosen screw H
.
2) Pull out hinge pin J and hinge bracket K.
Caution on reassembly:
a) When re-inserting eccentric hinge pm
F.
make certain that the eccentric part (the end w,th the
smallest diameter) is towards the
lell.
b) Re-locate collar D so that vibrating bracket G moves freely and without vertocal play
.
c) The extension finger on collar D should not touch ball bushing when needle penetrates to the
lell in the throat plate.
d) Spring A should be assembled with the longest tail to the lelt.
Adjustment of front to back setting of needle bar:
1) Remove presser loot.
2) Place a size 14 needle
No.
2020 (15
x
1) in the needle clamp
.
Check:
1) Install a straight stitch throat plate
.
2) Loosen screw
B.
3) Pos ition the needle bar vibrating bracket G so that the needle will enIer needle ho
le.
4) Turn hand wheel until the needIe is lowered into rhe throat plate needle hole
u
p
10
rhe needle
eye
.
5) In this position. the needle should be centered in the needle hole relative
10
the fron
t
or
rear.
Setting:
1) Loosen the screws C and
E.
2) Rotate accentric hinge pin to left or right as required until needle ,s centered in the ho
le.
3) Tighten screw E and C
.
Note
:
Aller this adjustment. check the adjustments of stitch width lover stops and s,deways sett,ng
of needle bar as described under
m.
sideways setting of needle bar as descnhed under
liJI
and adjustments given under
IEJ
Check distance between needle and hook po,nt. ReadIust ,f
necessary
.
Adjustment of stops for sideways movement of needle bar
Note
:
Before doing this adjustment. check the adjustment of stitch width lever stops and sideways
setting
of needle bar as
in
m
and
sideways selling
of
needle
bar
as
m
1iJ1
Check:
1) Install general purpose throat plate
.
2) Set stitch width lever on
"
Straight Stitch
".
3) Set needle position lever to
"
Right Needle·
·.
4) The distance between the extension finger on collar D and the extension of ball bushing L
should be equal 2 thickness of normal writing paper
.
Setting:
1) Loosen screw
C
.
2) Position
collar
D to obtain distance described
above.
3) Tighten screw
C.
FORM 723 (1172)
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

252257259

Table of Contents