Siemens BPS242RF Operating Instructions page 2

Advertisement

Set the first switch on time
1.
Set the programming selector to position A1. The setting for the first switch on
time flashes.
2.
Turn the setting knob counterclockwise - to decrease the time, or clockwise + to
increase the time.
3.
When the required switch on time is displayed, move the programming selector
to any other position to confirm the setting.
Set the first switch off time
1.
Set the programming selector to position A2. The setting for the first switch off
time flashes.
2.
Turn the setting knob counterclockwise - to decrease the time, or clockwise + to
increase the time.
3.
When the required switch off time is displayed, move the programming selector
to any other position to confirm the setting.
Set the second switch on time
1.
Set the programming selector to position A3. The setting for the second switch
on time flashes.
2.
Turn the setting knob counterclockwise - to decrease the time, or clockwise + to
increase the time.
3.
When the required switch on time is displayed, move the programming selector
to any other position to confirm the setting.
Set the second switch off time
1.
Set the programming selector to position A4. The setting for the second switch
off time flashes.
2.
Turn the setting knob counterclockwise to decrease the time, or clockwise + to
increase the time.
3.
When the required switch off time is displayed, move the programming selector
to any other position to confirm the setting.
Set comfort temperature
1.
Set the programming selector to position
2.
The setting for the current comfort temperature flashes.
3.
Turn the setting knob counterclockwise - to decrease the temperature setting, or
clockwise to increase the temperature setting.
4.
When the required comfort temperature is displayed, move the programming
selector to any other position to confirm the setting.
Set energy saving temperature
1.
Set the programming selector to position
2.
The setting for the current energy saving temperature flashes.
3.
Turn the setting knob counterclockwise - to decrease the temperature setting,
or clockwise + to increase the temperature setting.
3.
When the required energy saving temperature is displayed, move the
programming selector to any other position to confirm the setting.
Note: Set the controller to RUN when all programming is completed.
Temporarily change current setpoint
1. The current programmed temperature can be changed temporarily when the
operating mode selector is in the AUTO position and the programming selector
in the RUN position.
2. Turn the setting knob slightly in either direction to display the current programmed
temperature, turn it counterclockwise to decrease the temperature, or clockwise to
increase the temperature .This new temperature is maintained until the next
switching time. The hand symbol is displayed when activated.
Changing
the batteries
Receiver
LED Signal Indicator
The signal is good when the
A solid red LED indicates that
* Note when SET is pressed, the
RF signal will not affect the output
for 15 min. After 15 min the
output and LED will not change if
no RF received. If RF received,
output and LED will follow the RF
data.
Room Unit : (Rear View)
.
Configuration instructions for the BOSS BPS242RF
The Transmitter BPS242RF room unit and the receiver BR1 are set to communicate (bonded) with each
other at the factory. If they fail to do so at installation or it is necessary to re bond the units due to loss of
communication please follow the following instructions.
Energy saving tips without sacrificing comfort
NOTE:
1.
Get 2 new alkaline batteries type AA, 1.5 V.
2.
Within 1 minute: Remove the battery holder, then the batteries, insert the new
batteries and replace the battery holder. The old, set values must be checked!
3.
Properly dispose of old batteries per environmental regulations.
LED is solid green.
there is no signal.
(Transmitter)
Mounting plate must be
removed to get access
to the back!
Learn Button
Press to learn
1. For room unit: Set the programming switch to RUN and the selector switch to AUTO.
2. If room unit is wall mounted remove from wall or if on table stand remove grey backing plate
3. For receiver, Reset by pressing the RESET button for 4 seconds.
4. On Receiver Press and release the SET button. This puts the receiver in learn mode.
5. On room unit Press and release the LEARN button on the back.
6. A green solid LED indicates a good signal, a red solid LED indicates no signal.
7. To test transmission, press the TEST button on the transmitter, this switches the relay to ON on
the receiver regardless of temperature. The RF TEST symbol appears on the display (1 s).
8. An orange LED indicates that the relay is on.
Do not allow room temperatures to exceed 21 ºC.
You can press the SET button on the receiver to manually switch ON/OFF for a faulty
room unit or transmission signal.
LED Relay Indicator
Orange LED indicates relay is on.
SET Button *
Press this button to manually override
instructions from the Room Unit – Use this
when there has been a loss of power to
the Room Unit
RESET Button
Press and hold this button to reset the
Receiver to factory default settings
TEST Button
Used for testing transmission.