Maintenance Schedules - Navien NHB-055H User's Information Manual

Table of Contents

Advertisement

If hot water will not flow and you
Note
suspect that the boiler is frozen,
contact an authorized technician or
licensed professional.
This boiler requires very little
maintenance, however a qualified
technician should inspect the boiler at
the beginning of every heating season
and/or when there is a problem.

4.5 Maintenance Schedules

Owner maintenance
Check the boiler area is free
of combustible/flammable
materials and air contaminants.
Daily
Check the pressure/temperature
gauge for signs of higher than
normal pressure.
Visually inspect the vent
piping for signs of leakage and
blockage.
Monthly
Visually inspect the burner
flames.
Inspect the condensate trap and
the PVC fittings.
Test the LWCO for proper
Periodically
operation.
Inspect boiler piping (gas and
water) for leaks.
Every 6
months
Test to make sure the relief valve
is operating normally.
Non-
Shut boiler down (unless boiler
heating
is used for domestic hot water).
season
18
Maintaining the Boiler
Service technician (See the following instructions)
General:
Address reported
problems.
Inspect interior; clean
and vacuum if necessary.
Clean condensate trap
and fill with fresh water.
Check for leaks (water,
gas, flue, condensate).
Verify flue and air lines
in good condition and
sealed tight.
Check system water
pressure/system piping/
expansion tank.
Annual Start-up
Check control settings.
Check ignition and
flame rod (clean and
reposition).
Check wiring and
connections.
Inspect flame (stable,
uniform).
Inspect flame signal.
If combustion or
performance indicate need:
Flush heat exchanger.
Remove and clean air
intake filter.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nhb-080hNhb-110hNhb-150h

Table of Contents