Electrolux Dometic RM 6270 Manual page 27

Table of Contents

Advertisement

3. Wiring diagram with automatic ignition and no interior light
Battery connection 12V/24V -
A = Ground heating element DC, white
B = Heating element DC-,
C = Ground automatic ignition, black
D = Automatic ignition
4. Wiring diagram with automatic ignition and interior light
Battery connection 12V/24V -
A = Ground heating element DC, white
B = Heating element DC-,
red
C = Ground, automatic ignition black
and interior light,
D = Automatic ignition and
violet
interior light
* resistor (replaced by a bridge for 24V battery voltage)
battery connection
12V/24V --
red
violet
ground
heating-
element
~
AC
battery connection
12V/24V --
ground
thermo cut-off current
heating-
element
~
AC
27
spark plug
to casing
thermo cut-off current
to casing
spark plug
* resistor
to casing
light DC --
to casing
reigniter
~
mains connection
from battery
to casing
~
mains connection
to casing