How To Know To Temperature Of Each Thermistor At Operating Condition; Error Display - LG F0L9DYP2 Series Service Manual

Table of Contents

Advertisement

7-4. HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR AT
OPERATING CONDITION.
Thermistor in tub : Press the [Delay End + Temp.] button.
Thermistor in dry duct : Press the [Delay End + Normal Dry] button.

7-5. ERROR DISPLAY.

If you press the START/PAUSE button when an error is displayed, any error except
and the machine will go into the pause status.
In case of
,
if the error is not resolved within 4 min., power will be turned off automatically and the error code will
blink. But in the case of
ERROR
WATER INLET
1
ERROR
UNBALANCE
2
ERROR
DRAIN
3
ERROR
OVER FLOW
4
ERROR
PRESSURE
5
SENSOR
ERROR
DOOR OPEN
6
ERROR
HEATING
7
ERROR
,
if the error is not resolved within 20 sec., or the in case of other errors,
, power will not be turned off.
SYMPTOM
Correct water level (248) is not reached within 8 minutes after
water is supplied or it does not reach the preset water level
within 25 minutes.
The load is too small.
The appliance is tilted.
Laundry is gathered to one side.
Non distributable things are put into the drum.
Not fully drained witnin 10 minutes.
Water is over flowing(under 21.3kHz).
※ If
automatically.
The SENSOR SWITCH ASSEMBLY is out of order.
Door not all the way closed.
Loose electrical connections at Door switch and PWB Assembly.
The DOOR SWITCH ASSEMBLY is out of order.
The THERMISTOR is out order.
CAUSE
is displayed, drain pump operates to drain water
15
FOR LG TECHNICIAN
will disappear