Smoke Emitter Cabin Pressure Leak Test - Hitachi ZX225USLC-5 Parts And Service Manual

Table of Contents

Advertisement

HITACHI
ZX225USLC-5 Excavator
* Do not handle until MSDS & all safety precautions have been read and understood. Use personal protective equipment as required.
Before use, carefully read the product label. Safe work practices are advised to avoid eye or skin contact and inhalation. Observe good personal hygiene,
including washing hands before eating. Prohibit eating, drinking, and smoking in contaminated areas. Avoid inhalation. Mechanical extraction ventilation is
recommended when the removal of atmospheric contaminants is required. Maintain dust / fume levels below the recommended exposure standard. For small
amounts, absorb with sand, vermiculite or similar and dispose of at an approved landfill site.
For Professional Use Only – keep out of reach of children.
Do not ignite near or around flammable materials.
Use only in well-ventilated areas, outdoors, and/or with proper respiratory protection.
Persons with respiratory sensitivity should avoid exposure to any smoke.
Concentrated smoke may cause severe burns to the skin, eyes, or respiratory system.
Improper use may result in sufficient inhalation of smoke to cause respiratory tract irritation and lung damage.
Harmful if swallowed.
Use only as directed. Do not handle until all safety precautions, including Safety Data Sheet, have been read and understood.
The product contains hexachloroethane. Wear protective clothing. If exposed or concerned, get medical advice. Store in a cool,
dry, secure location. KEEP OUT OF REACH OF CHILDREN. Dispose of contents/container per location regulations. When used as
directed, exposure should be limited and usually poses no hazard because the hexachloroethane is consumed inside the tube as
smoke is produced.
1.
Ensure other workers in close proximity are informed of use. Place on a non-combustible container, away from flammable
materials.
2.
Place at Blower intake, or upwind of target area, or near centre of space.
Orient "Smoke Issues Here" toward air stream, away from surfaces. Place candle on a flame / heat resistance plate – if not
3.
it will melt into the plastic surface.
4.
Ensure smoke will not create any hazard where it is anticipated to go.
Ignite emitter inside the cabin using site approved device i.e., solder torch or 'lighter' and conduct smoke test.
5.
Do not touch or hold smoke generator after ignition – item becomes very hot & remains hot after use.
6.
1.
The pressuriser system is switched on (TEST MODE).
2.
Hold the smoke emitter angled down.
Ignite emitter using site approved ignitor i.e., solder torch or 'lighter'.
3.
4.
When the product ignites, remove the lighter.
5.
If the product flames up, blow out the flame.
6.
Place the emitter in a non-flammable container and place it inside the cabin at floor level and close the door/windows.
7.
Observe smoke leaks to indicate worn-out or broken seal locations. Check leakage points outside the cabin.
8.
Do not come into contact with or inhale smoke haze.
9.
Wait until the smoke haze completely disperses before re-entering the cabin. Open door to allow sufficient ventilation of
smoke prior to entering cabin.
*This SWP does not necessarily cover all possible hazards associated with this equipment and should be used in conjunction with other references. It is designed as a guide to be used to compliment training and
as a reminder to users prior to equipment use.
WARNING
DANGER
Directions: (Smoke Bomb)

Smoke Emitter Cabin Pressure Leak Test

SMOKE EMITTER CABIN PRESSURE LEAK TEST
SMOKE GENERATOR TQ7621AT30S.pdf
Link to MSDS:
Personal Protective Equipment (PPE)
Safety glasses must be worn at all times.
Sturdy footwear with rubber soles must be worn.
Respiratory protection devices may be required.
Gloves may be worn.
Pre-operational Safety Checks
Locate and ensure you are familiar with all machine
operations and controls.
Check work area and walkways to ensure no slip/trip
hazards are present.
Ensure the work area is clean and clear of any flammable
material & fire extinguish device is present.
Operational Safety Checks
Ensure the machine is correctly isolated / immobilized.
Ensure other persons do not inhale smoke haze.
Take care and do not place a lit emitter close to a
flammable surface.
Ending Operations and Cleaning Up
Leave the work area in a safe, clean, and tidy state.
Potential Hazards
Falls
Fumes
Fire
May cause cancer
Exposure is highly unlikely when the product is used as directed. Direct
contact with the product does not occur.
Don't
Do not use if an open flame is forbidden.
Never leave the emitter [cabin test] unattended.
15