Siemens SINUMERIK ONE MCP 2400 Equipment Manual page 24

Hide thumbs Also See for SINUMERIK ONE MCP 2400:
Table of Contents

Advertisement

Technical data
 
Temperature change
Relative humidity
Permissible change in the relative humidity
Pollution degree
Mechanical environmental conditions
Classification of the mechanical environ‐
ment
Vibration load during operation
Shock load during operation with shock-
sensitive components
EMC conducted / radiation
1) The system installer ensures the system is sealed properly according to IP65, IP classification has not been
checked by UL, UL TYPE 1.
2) Open-type equipment according to UL 61010.
3) The customer must ensure that the product, with the rear cover to be attached by the customer, meets
the requirements for flame resistance of the material according to UL 94 V-1 and the mechanical stability /
fire protection requirements / touch protection according to UL 61010.
4) If power supply units with primary-side supplies up to 600 V AC (line-to-neutral voltage) have to be
deployed, the transient voltages on the primary side of the power supply unit must be limited to 4000 V.
5) Connect the device only to a 24 V DC power supply that is compliant with protective extra-low voltage
(PELV) requirements according to UL 61010.
Note
The 24 V DC power source must be adapted to the input data of the device (see "Electrical data").
Note
In a residential environment, this product can cause high-frequency interference, which may
make interference suppression measures necessary.
• Have the installation and commissioning with appropriate radio interference suppression
measures performed by qualified personnel.
Note
Damage to components by coolants and lubricants
The SINUMERIK operator components have been designed for industrial use, particularly on
machine tools and production machines. This also takes into account the use of commercially
available coolants and lubricants. The use of aggressive compounds and additives can damage
components and result in their failure.
Avoid contact between the operator components with coolants and lubricants, as resistance to
all coolants and lubricants cannot be guaranteed.
24
MCP 2400
Max. 30 K/h
5 ... 90% (without condensation)
Max. 6%/h
2 (only use indoors)
Class 3M2 according to EN 60721-3-3
Frequency range: 10 – 200 Hz
Deflection at 9 – 18 Hz: 1.5 mm
Acceleration at 18 – 200 Hz: 2 g
Acceleration: 5 g
Shock duration: 30 ms
Load: 3 x in each direction
Class C2 according to EN 61800-3
Equipment Manual, 08/2023, A5E50324707B AB
Acceleration: 15 g
Shock duration: 11 ms
ONE MCP Part 2: MCP 2400