Custom Wiring Example - National Instruments NI 6535 User Manual

Cable adapter
Table of Contents

Advertisement

Custom Wiring Example

© National Instruments Corporation
You can use different wiring schemes to connect the PFI channels in
multiple configurations. This section describes a burst handshaking
example using an NI 653x cable adapter to provide compatibility between
an NI 6533/6534 and an NI 6535/6536/6537 where the fixture is
configured to work with the NI 6533/6534. Without changing the fixture
setup, the adapter and software can be changed to maintain functionality.
The NI 653x cable adapter can be configured using 22- to 26-gauge wire as
shown in Figure 7.
6535/6/7 PFI
J1
This custom wiring results in the signal assignments shown in the following
table.
VHDCI
NI 6535/6536/6537
PFI_0
PFI_1
PFI_4
W1
6533/4
PFI
7
5
6
4
5
3
4
2
3
2
1
0
1
0
J4
J3
J2
Figure 7. Example Connectivity
Table 4. Example Connections
PFI_2 (REQ/Pause)
PFI_6 (ACK/Ready for Transfer)
PFI_4 (CLK OUT)
11
ACK/Ready for Transfer
CLK OUT
REQ/Pause
68-Pin DAQ
NI 6533/6534
NI 653x Cable Adapter User Guide