Sas/Sata Connectors; Figure 6. Intel ® Raid Controller Rs2Sg244 Sas/Sata Connectors - Intel RS2SG244 User Manual

Integrated raid controller
Table of Contents

Advertisement

The drive failure tones repeat until the problem is corrected, or until the alarm is silenced
or disabled. The alarm can be silenced or disabled on the controller's properties page in
the BIOS Console or by using the failed drive options pane in the Intel
Console 2.
Silencing the alarm is temporary. If the cause of failure still exists or if an additional
failure is detected, then the alarm sounds again when the system is rebooted. Disabling the
alarm is persistent across errors and reboots. When the alarm is disabled, a failure does not
cause it to sound until it is re-enabled.
The rebuild alarm tone functions differently. It remains ON during the rebuild. After the
rebuild completes, an alarm with a different tone sounds to signal that the rebuild is
complete. This is a one-time, non-repeating tone.
LED Placement and Function
The Intel
One surface-mounted heartbeat LED (Green Color) to indicate SAS2108 activity.
Another surface-mounted system error LED (Amber Color) to indicate a board
error.

SAS/SATA Connectors

The Intel
SATA signal connector and one external SFF8088 SAS / SATA signal connector. Both
SFF8087 and SFF8088 connectors provide support for four SAS / SATA ports. The
sideband signals are configured to adhere to the SFF-8485 Specifications for SGPIO
support.
Figure 6. Intel
16
®
RAID Controller RS2SG244 contains the following LEDs:
®
Integrated RAID controller RS2SG244 provides six internal SFF8087 SAS /
Internal connector
®
RAID Controller RS2SG244 SAS/SATA Connectors
External connector
Intel® RAID Controller RS2SG244 Hardware User's Guide
®