Measurements And Adjustments; Voltage Chart Of A-Board; Voltage Chart Of P-Board - Panasonic TC-L32E5B Service Manual

Table of Contents

Advertisement

8 Measurements and Adjustments

8.1.

Voltage chart of A-board

Set A-Board to a dummy set and check the satisfaction with the specified voltage as following table.
8.2.

Voltage chart of P-board

Set P-Board to a dummy set and check the satisfaction with the specified voltage as following table.
VOLTAGE
PANEL12V
USB_5V
SUB5V
SUB3.3V
SUB1.8V
SUB1.5V
SUB1.1V
AVDD 12.6V
VON31V
VOFF2_-6V
VOLTAGE
TEST POINT
5.8V
TP7507
15.6V
TP7508
40V
TP7501
TEST POINT
SPECIFICATION
TP4004/TP4005
11.45V - 12.55V
TP5440
4.80V - 5.25V
TP5420
4.95V - 5.65V
TP5400
3.17V - 3.43V
TP8700
1.7V - 1.9V
TP8101
1.435V - 1.585V
TP8100
1.10V - 1.22V
TP4101
12.6V ± 2V
TP4067
31V± 3.1V
TP4066
-5.7V ± 0.6V
SPECIFICATION
OPERATE
6.2 + 0.5 / -1.0 V
15.6 ± 0.8 V
40 ± 4V
29
STBY
5.6 + 1.1 / -0.4V
15.6 ± 0.8 V
≤ 61V
TC-L32E5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc-l32e5