- Twist the lead wires to reduce the radio interference and induction of a high voltage
surge from the outside (See Art01518).
2. Connect the DC power supply (See
Art01509):
- Remove the two (2) screws that attach
the junction cover.
- Remove the junction cover.
- Put each of the two (2) wires from the
battery through the ferrite core.
- Make a loop of the two (2) around and
back through the ferrite core.
- Put the two (2) wires through the
bushing of the junction cover.
- Push the DC input wires onto the DC
input terminals.
- Refer to the positive (+) and
negative (-) markings to make sure
that the connections are correct.
- Attach the junction cover with the two
(2) screws.
- Put the two (2) wires through the wire
strain relief.
- Attach the wire strain relief to the refrigerator cabinet with the self-tapping screw.