Introduction
The KL08NSB 24V wiring centre forms the heart of a Underfloor Heating controls system. It allows
easy and quick connection of thermostats and actuators. It has integrated pump and boiler control
module and overload protection. KL08NSB 24V wiring centre is adapted to work with NC and
NO type actuators (normally closed and normally open). Up to 8 thermostats can be connected
to the KL08NSB 24V, while KL04NSB 24V extension allows to connect additional 4 thermostats (12 in
total). NOTE! 24V/230V transformer is included with the set with the control box!
Product compliance
This product complies with the essential requirements and other relevant provisions of the following
EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, RoHS directive 2011/65/EU.
The full text of the EU Declaration of Conformity is available at the following internet address:
www.saluslegal.com.
Safety information
Use in accordance with national and EU regulations. Device is intended for indoor use only
in dry conditions. Product for indoor use only. Installation must be carried out by a qualified
person in accordance to national and EU regulations.
B
Before attempting to setup and install, make sure that KL08NSB 24V is not connected to any
power source. Installation must be carried out by a qualified person. Incorrect installation may
cause damage to the wiring centre. The KL08NSB 24V should not be installed in areas where it
may be exposed to water or damp conditions.
Technical Information
Power Supply
24 V AC 50 Hz
Total Load Max
5 A
Pump / Boiler Relay Load Max
3 A
Inputs
External clock (24 V)
Outputs
Pump control (NO/ COM)
Boiler control (NO/COM)
Terminals for actuators (24V)
Dimensions [mm]
355x 85x 67
Wiring centre description
1. Cartridge fuse 5 x 20 mm 12 A
2. Power supply
3. NSB function terminals
4. NC/NO jumper (actuator type)
1
L1
KL08NSB
Manual
1. Fuse
Note: Replace the fuse only when the wiring centre is disconnected from power supply
(24 V ~).
Main fuse is located under the housing cover next to power supply terminals and secures the wiring
centre and the devices connected to it. Use ceramic tube fast blow 250 V ROHS fuses (5x20 mm) with
nominal max current 12,5 A. To replace fuse remove the fuse holder with a flat screwdriver and pull
out the fuse.
2. Power Supply
230 V AC
L
N
230V/24V transformer
(in the set)
Power supply for wiring centre is 24 V ~ 50Hz.
Two wire installation should be made in accordance
L1
L2
with the applicable regulations
3. NSB (Night Set Back reduction) function and thermostats grouping
NSB function is activated in non-programmable Salus thermostats of the Expert NSB, HTR, BTR
series via external signal. NSB 24 V signal (night-time temperature reduction) is sent via an external
timer or programmable thermostat connected to the KL08NSB 24V wiring centre. Non-programmable
thermostats are receiving NSB signal and reducing setpoint temperature (by switching to eco mode).
All thermostats have to be connected using a 4-wire cable (min. 4 x 0,75 mm
5. Delay jumper
6. Boiler control output
7. Pump control output
8. Actuators connection
2
3
L2
L1
L1
L2
L1
L2
L1
L2
L1
24VAC
group i
NSB function application in combination with thermostats grouping.
• OPTION 1
jumper
L
1-4
5-8
• OPTION 2
no jumper
5-8
L
1-4
• OPTION 3
2
, max. 4 x 1,5 mm
2
).
L
1-4
5-8
11
L2
L1
L2
L1
L2
L1
L2
L1
L2
8
group ii
One Master thermostat which is common for thermostats from Group 1
and Group 2 (one programmable thermostat e.g. HTRP(50) 24V, other
thermostats are non-programmable e.g. HTR(20) 24V).
Two Master thermostats. One for Group 1 and one for Group 2 (two
programmable thermostats e.g. HTRP(50) 24V, other thermostats are
non-programmable e.g., HTR(20) 24V)).
One external clock which is common for thermostats from Group 1
and Group 2 (one external clock + daily regulators e.g. HTR(20) 24V)).
9. Serial connector for the KL04NSB 24V extension
10. Reset button
11. Thermostats connection
4
5 10
Reset
0
O
1
2
3
4
7
6
• OPTION 4
Two external clocks. One for Group 1 and one for Group 2 (two external
clocks + non-programmable regulators e.g. HTR(20) 24V)).
L
1-4
5-8
4. NC/NO jumper
Reset
Select the type of the thermoelectric actuator connected to the wiring centre:
NC – actuator normally closed
0
NO – actuator normally opened
O
Jumper position change must be refreshed in the memory by pressing
the Reset button (short press).
5. Delay jumper
Reset
Boiler off delay time.
0
Note: Pump (Pump output) and boiler (Boiler output) always starts
3 minutes after receiving the heating signal from any thermostats
O
connected to wiring centre. Pump stops 3 minutes after the last call for
heating sent by the thermostat and the heat source (boiler) will turn off
1
2
3
4
after the time set on Delay jumper.
Jumper position change must be refreshed in the memory by pressing
the Reset button (short press).
1
2
3
4
9