Download Print this page

Salus SS901ZB Installation & Quick Start Manual

Water leak sensor

Advertisement

Quick Links

In the Box
Water Leak Sensor w/ Battery
Stand
(1x CR2, 3V Lithium)
P
I
AIRING
NSTRUCTIONS
• Follow your system's instructions to prepare to add devices to the
system.
• Remove the Face Plate from the sensor by turning the Face Plate
counter-clockwise and pull the battery tab to start the pairing
process.
• When the sensor is detected and added to the system, replace the
Face Plate by aligning the dots and turning the Face Plate clockwise.
• Make sure the dots are fully aligned for a proper seal, then proceed
to the sensor installation.
I
I
NSTALLATION
NSTRUCTIONS
• Identify a level surface for the sensor, where water will likely
accumulate in the event of a leak. If the sensor is too wide for
placement at the desired location, the stand can be used for a
narrower profile.
Sensor Cable
Installation/
Quick-start Guide
I
S
C
NSTALLING THE
ENSOR
• To install the Sensor Cable, first run the cable to the desired location,
and fasten the winged end of the Sensor Cable into place. Note that
the tips are angled to improve the sensing ability when the tips are
near a surface.
Surface Install
For tighter
• Insert the square end of the Sensor Cable into the terminals on the
locations or
stand.
locations with
• Screw down both terminals until the cable is firmly held in place
radio problems,
• Mount the Stand to the wall or other surface using the supplied
use the
double-sided adhesive pad or screws.
included
• Insert the Water Leak Sensor into the stand to begin operation.
Sensor Cable.
Installation/Quick Start Guide: Water Leak Sensor (SS901ZB)
Screws and Anchors
Adhesive Pad
(O
)
ABLE
PTIONAL
Sump Install
Visit www.salusinc.com for the User Manual
Tools Needed
Note:
Additional equipment may be required due
to building construction or materials, or other
radio interference that may reduce the radio
range.
#1 Phillips Screwdriver
T
S
ESTING THE
ENSOR
• To test the sensor, remove it from the stand or floor
• Insert the sensor into the stand 90 degrees from upright in either
direction to short the contacts on the sensor.
• The sensor will send a message to the connected home system
indicating a water leak. The LED will not light up to preserve battery
life.
R
B
EPLACING THE
ATTERY
• Grasp the top of the sensor Face Plate, rotate counter-clockwise
and lift from the sensor Body.
• Grasp the battery from both ends and lift to remove the battery
from the sensor.
• Insert a new battery into the sensor, observing the proper polarity.
• Position the sensor Face Plate over the Sensor Body, aligning the
dots on the Face Plate and Body, then rotate clockwise to align the
dots again to close.
Version 2

Advertisement

loading

Summary of Contents for Salus SS901ZB

  • Page 1 Installation/Quick Start Guide: Water Leak Sensor (SS901ZB) Visit www.salusinc.com for the User Manual In the Box Tools Needed Note: Additional equipment may be required due to building construction or materials, or other radio interference that may reduce the radio range.
  • Page 2 • Remove the sensor Face Plate. WARNING: Changes or modifications to this unit not expressly approved by the SALUS North America, Inc. (“Salus”) warrants that for a period of five (5) years • Remove the battery. party responsible for compliance could void the user’s authority to operate the (“Warranty Period”) from the date of purchase by the consumer (“Customer”),...