Carrier FY5B Installation Instructions Manual page 6

Fan coil units
Table of Contents

Advertisement

FAN COIL
THERMOSTAT
(CONTROL)
RED
R
GRY
G
BRN
C
WHT
W
2
VIO
E
BLU
L
O
Y
Fig. 13 - - Wiring Layout Heat Pump Unit
(Cooling and 2- -Stage Heat with
1 Outdoor Thermostat)
FAN COIL
THERMOSTAT
(CONTROL)
RED
R
GRY
G
BRN
C
WHT
W
2
L
E
O
Y
C
1
4
7
C
EMERGENCY HEAT RELAY
Fig. 14 - - Wiring Layout Heat Pump Unit (Cooling and
2- -Stage Heat with 2 Outdoor Thermostats)
FAN COIL
THERMOSTAT
(CONTROL)
R
R
G
G
C
C
W
W
2
W
E
E
L
O
Y
Fig. 15 - - Wiring Layout Heat Pump Unit
(Cooling and 2- -Stage Heat for Manufactured Housing)
Refer to outdoor unit wiring instructions for any additional wiring
procedure recommendations.
HEAT PUMP
(CONTROL)
R
R
G
C
C
W
2
E
W
2
ODTS
W
3
O
Y
A94061
HEAT PUMP
(CONTROL)
R
R
G
C
C
W
2
W
2
BLU
ODTS1
W
3
VIO
E
ODTS2
O
Y
9
6
3
A94062
HEAT PUMP
(CONTROL)
R
C
W
2
2
3
ODTS
O
Y
A03088
Transformer Information
Transformer is factory- -wired for 230v operation. For 208v
applications, disconnect the black wire from the 230v terminal on
transformer and connect it to the 208v terminal. (See Fig. 16.)
SECONDARY
Fig. 16 - - Transformer Connections
Heater Staging
CAUTION
!
PROPERTY DAMAGE HAZARD
Failure to follow this caution may result in product or
property damage.
If W2, W3, and E on any 3 stage heater (18, 20, 24, or
30kW) are individually connected as with outdoor
thermostats or any other situation, emergency heat relay must
be used. This relay is in kit Part No. KHOT0201SEC and is
normally used with kit Part No. KHAOT0301FST for 2
outdoor thermostat systems.
The controls are factory circuited for single- -stage operation. For
2- -stage operation, use outdoor thermostat kit Part No.
KHAOT0301FST, and for 3- -stage use both kits Part No.
KHAOT0201SEC and KHAOT0301FST.
When 2 stages are desired, cut W3 at the W2 wire nut, strip and
reconnect per the thermostat kit instruction. (See Fig. 14.) When 3
stages are desired, cut the W2 wire nut off and discard. Strip W2,
W3, and E and reconnect per thermostat kit instructions. (See Fig.
14.)
NOTE: When 3 stages are used or anytime the E terminal is not
tied to W2, the emergency heat relay, part of outdoor kit Part No.
KHAOT0201SEC must be used.
C. Manufactured Housing
In manufactured housing applications, the Code of Federal
Regulations, Title 24, Chapter XX, Part 3280.714 requires that
supplemental electric heat be locked out at outdoor temperatures
above 40_F (4_C), except for a heat pump defrost cycle. Refer to
Fig. 15 for typical low voltage wiring with outdoor thermostat.
6