Gigabyte E283-Z91-AAD1 User Manual

Gigabyte E283-Z91-AAD1 User Manual

Rack server - amd epyc 9004
Table of Contents

Advertisement

Quick Links

E283-Z91-AAD1
E283-Z91-AAV1
Rack Server - AMD EPYC™ 9004
2U DP 4-Bay SATA/SAS4
Dual 1600W (240V) 80 PLUS Platinum redundant power supply (AAD1)
Dual 1600W (240V) 80 PLUS Titanium redundant power supply (AAV1)
User Manual
Rev. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte E283-Z91-AAD1

  • Page 1 E283-Z91-AAD1 E283-Z91-AAV1 Rack Server - AMD EPYC™ 9004 2U DP 4-Bay SATA/SAS4 Dual 1600W (240V) 80 PLUS Platinum redundant power supply (AAD1) Dual 1600W (240V) 80 PLUS Titanium redundant power supply (AAV1) User Manual Rev. 1.0...
  • Page 2 GIGABYTE's prior written permission. Documentation Classifications In order to assist in the use of this product, GIGABYTE provides the following types of documentation:  User Manual: detailed information & steps about the installation, configuration and use of this product (e.g.
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Pieces of additional information related to the current topic. CAUTION! Precautionary measures to avoid possible hardware or software problems. WARNING! Alerts to any damage that might result from doing or not doing specific actions.
  • Page 4 Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 6 Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that can be gripped with fin-gertips or with a pair of fine needle nosed pliers. If the jumpers do not have such a tab, take care when us- ing needle nosed pliers to remove or install a jumper;...
  • Page 7: Table Of Contents

    Table of Contents Chapter 1 Hardware Installation ................... 11 Installation Precautions .................. 11 Product Specifications ..................12 System Block Diagram ................... 16 Chapter 2 System Appearance ..................17 Front View ...................... 17 Rear View ....................... 18 Front Panel LEDs and Buttons ............... 19 RoT LEDs .......................
  • Page 8 4-3-1 CDCR114 .......................51 Backplane Board Storage Connector ............52 4-3-2 CBP2025 (Rear System Storage Board) ..............52 Chapter 2 BIOS Setup ....................53 The Main Menu ....................55 Advanced Menu ..................... 58 5-2-1 Trusted Computing ....................60 5-2-2 PSP Firmware Versions ..................61 5-2-3 Legacy Video Select ....................62 5-2-4 AST2600 Super IO Configuration ................63...
  • Page 9 Server Management Menu ................154 5-6-1 System Event Log ....................156 5-6-2 View FRU Information ..................157 5-6-3 BMC Network Configuration .................158 5-6-4 IPv6 BMC Network Configuration .................159 Security Menu ....................160 5-7-1 Secure Boot ......................161 Boot Menu ....................163 Save & Exit Menu ..................165 5-10 BIOS Recovery ....................
  • Page 10 This page intentionally left blank - 10 -...
  • Page 11: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 12: Product Specifications

    Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related information without prior notice. System Security Server Socket Operating Properties Š 2U Dimension Š 438 (W) x 87.5 (H) x 625 (D) mm System fan Power Supply Š...
  • Page 13 Storage Rear side: Š 4 x 2.5" SATA/SAS4 hot-swappable bays, via CRS2810 from CPU_1 SAS card is required for SAS devices support Š Supported RAID Š Depends on SAS add-on card Expansion Slot PCIe Cable x 6: 3 x PCIe x16 (Gen5 x16) FHHL slots, from CPU_0 Š...
  • Page 14 Operating Properties Š Optional TPM2.0 kit: CTM010 System fan Power Supply Power Supply E283-Z91-AAD1 Š Dual 1600W (240V) 80 PLUS Platinum redundant power supply AC Input: Š 100-120V~/ 12A, 50-60Hz Š 200-240V~/ 10A, 50-60Hz DC Input: Š 240Vdc/ 10A DC Output: Š...
  • Page 15 System Š Aspeed® AST2600 management controller Management Š GIGABYTE Management Console (AMI MegaRAC SP-X) web interface Š Dashboard Š HTML5 KVM Š Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) Š Sensor Reading History Data Š FRU Information Š SEL Log in Linear Storage / Circular Storage Policy Š...
  • Page 16: System Block Diagram

    System Block Diagram SATA x4 Occupied by CRS2810 Occupied by CRS2810 4-bay 2.5" SATA (rear) 4 x SATA ports 4 x SATA ports PCIe3.0 x4 PCIe3.0 x2 PCIe3.0 x4 12-Channel DDR5, 12 x DIMMs 12-Channel DDR5, 12 x DIMMs Speed up to 4800 MHz Speed up to 4800 MHz CPU0 CPU1...
  • Page 17: Chapter 2 System Appearance

    Chapter 2 System Appearance Front View Description Front Panel LEDs and Buttons USB 3.2 Gen1 Port x 2 • Refer to section 2-3 Front Panel LEDs and Buttons for a detailed description of the function of the LEDs. System Appearance - 17 -...
  • Page 18: Rear View

    Rear View SLOT11 SLOT10 SLOT12 SLOT9 SLOT8 SLOT5 SLOT7 SLOT6 SLOT4 SLOT3 PSU2 PSU1 SLOT2 SLOT1 Description Description Mini DP Port Server Management LAN Port ID LED OCP 3.0 Slot (Option/SFF) USB 3.2 Gen1 Port x 2 PCIe Slot 1GbE LAN Port x 2 2.5”...
  • Page 19: Front Panel Leds And Buttons

    Front Panel LEDs and Buttons No. Name Color Status Description Reset Button Press this button to reset the system. Press this button for the server to generate a NMI to the NMI button processor. If multiple-bit ECC errors occur, the server will effectively be halted.
  • Page 20: Rot Leds

    RoT LEDs ID LED Status LED LED on Front panel (Note5) ID LED Status LED EC Firmware (FW) Authentication fail or not exit EC FW is broken or not exit (Note1) Authenticating/Recovering BMC/BIOS Images Authenticating Images Blinks Blue Blinks Green Recovering BMC Active Flash 4 times per second 4 times per second...
  • Page 21 Active Flash Authentication (AUTH) Fail Blinks Blue Blinks Green BMC : AUTH Fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Amber BIOS : AUTH fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Green 2 times per second 2 times per second...
  • Page 22: Rear System Lan Leds

    Rear System LAN LEDs Name Color Status Description Yellow 1 Gbps data rate 1GbE Speed Green 100 Mbps data rate 10 Mbps data rate Link between system and network or no access Green 1GbE Link / Blink Data transmission or reception is occurring. Activity LED No data transmission or reception is occurring.
  • Page 23: Power Supply Unit Led

    Power Supply Unit LED PSU LED State Description No AC power to all power supplies 1Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updateing mode AC cord unplugged or AC power lost; with a second power supply in parallel still with AC input power Amber Power supply critical event causing shut down:...
  • Page 24: Hard Disk Drive Leds

    Hard Disk Drive LEDs 3.5” HDD LED #1 LED #2 HDD Present RAID SKU LED #1 Locate Rebuilding HDD Access Fault (No Access) Green ON(*1) BLINK (*2) Disk LED (LED on Back Panel) Amber No RAID configuration Removed HDD Green ON(*1) (via HBA) Slot (LED on...
  • Page 25: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
  • Page 26: Removing And Installing The Chassis Cover

    Removing and Installing the Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the chassis cover: Remove the screw securing the chassis cover. Unlock the plastic handle and pull the grip handle to open the panel cover.
  • Page 27: Removing And Installing The Hard Disk Drive

    Removing and Installing the Hard Disk Drive Read the following guidelines before you begin to install the hard disk drive: • Take note of the HDD tray orientation before sliding it out. • The tray will not fit back into the bay if it is inserted incorrectly. •...
  • Page 28: Removing And Installing The Fan Duct

    Removing and Installing the Fan Duct Follow these instructions to remove the fan duct: Lift up to remove the fan duct. To reinstall the fan duct, align the fan duct with the guiding groove. Push down the fan duct until it is firmly seated on the system.
  • Page 29: Removing And Installing The Heat Sink

    Removing and Installing the Heat Sink Read the following guidelines before you begin to install the heat sink: • Always turn off the computer and unplug the power cord from the power outlet before installing the heat sink to prevent hardware damage. •...
  • Page 30: Removing And Installing The Cpu

    Removing and Installing the CPU Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 31 • Lock the CPU by using a Torx T20 screwdriver to tighten screw. • When installing the heatsink to CPU, use a Torx T20 screwdriver to tighten 6 captive nuts in sequence as 1-6. • The screw tightening torque: 13.5 ± 0.5 kgf-cm. •...
  • Page 32: Removing And Installing Memory

    Removing and Installing Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
  • Page 33: Removing And Installing A Memory Module

    3-6-2 Removing and Installing a Memory Module Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR5 DIMMs on to this motherboard.
  • Page 34: Memory Population Table

    3-6-4 Memory Population Table EPYC Memory Speed based on DIMM Population (One DIMM per Channel) DIMM Population DIMM Max EPYC 9004 Type DDR5 Frequency (MT/s) DIMM 0 1R (1 Rank) 4800 RDIMM 2R (2 Ranks) 4800 2S2R (4 Ranks) 4800 3DS RDIMM 2S4R (8 Ranks) 4800...
  • Page 35: Removing And Installing The Pcie Card

    Removing and Installing the PCIe Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered off and all power sources have been disconnected from the server prior to installing a PCIe card.
  • Page 36 System Hardware Installation - 36 -...
  • Page 37: Installing The Mezzanine Card

    Installing the Mezzanine Card 3-8-1 Installing the OCP 3.0 Mezzanine Card Use of the following type of OCP 3.0 NIC is recommended: • OCP 3.0 SFF with pull tab • OCP 3.0 SFF with ejector latch Save the black M3 screws in the event that you need to re-install the cover. Follow these instructions to install an OCP 3.0 Mezzanine card: Remove the two screws securing the OCP 3.0 card slot cover.
  • Page 38: Installing The M.2 Device And Heat Sink

    Installing the M.2 Device and Heat Sink CAUTION The position of the stand-off screw will depend on the size of the M.2 device. The stand-off screw is pre-installed for 22110 cards as standard. Refer to the size of the M.2 device and change the position of the stand-off screw accordingly.
  • Page 39: Replacing The Fan Assembly

    3-10 Replacing the Fan Assembly • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to replacing a system fan.
  • Page 40: Removing And Installing The Power Supply

    3-11 Removing and Installing the Power Supply Follow these instructions to replace the power supply: Flip up and then grasp the power supply handle. Press the retaining clip on the right side of the power supply unit in the direction indicated. Pull out the power supply unit using the handle.
  • Page 41: Cable Routing

    3-12 Cable Routing CPU0 CPU1 Motherboard: FP_1 Front IO Board: FP_1 Front Panel LEDs and Buttons Cable Front IO Board: FP_1 Motherboard: FUSB_1 Front Panel USB 3 Ports Cable System Hardware Installation - 41 -...
  • Page 42 CPU0 CPU1 Motherboard: BP_ATX1 HDD Backplane Board Power Cable Front Fan board: ATX1 Motherboard: 12V_BP1 HDD Backplane Board Power Cable Front Fan board: 12V_BP1 Motherboard: 12V_BP2 HDD Backplane Board Power Cable Front Fan board: 12V_BP2 Motherboard: BP_ATX3 HDD Backplane Board Power Cable Rear HDD Board: BP_2X3 Motherboard: BP_ATX2 HDD Backplane Board Power Cable...
  • Page 43 CPU0 CPU1 Front Fan board: BP_1 HDD Backplane Board Signal Cable Rear Left HDD: BP_SERIES Motherboard: BP_1 HDD Backplane Board Signal Cable Rear Right HDD Board: BP_1 Rear Right HDD Board: BP_SERIES Rear Left HDD Board: BP_1 System Hardware Installation - 43 -...
  • Page 44 CPU0 CPU1 M.2 Module: SATA_RA4 Rear Right HDD Board: SL_SAS0 SATA Cable M.2 Module: SATA_RA2 Rear Left HDD Board: SL_SAS0 System Hardware Installation - 44 -...
  • Page 45 CPU0 CPU1 Motherboard: U2_P1_P3_0 Motherboard: U2_P1_P3_1 NVMe 8-9 NVMe 10-11 Front HDD Board: Front HDD Board: Cable Cable E1: U.2_8 F1: U.2_10 E2. U.2_9 F2. U.2_11 System Hardware Installation - 45 -...
  • Page 46 CPU0 CPU1 Motherboard: A1: U2_P0_P2_0 A2: U2_P0_P2_1 System Rear Side PCIe Cable A3: PCIE1_PWR1 (Power Cable/Reseved) Slot 3: -- Motherboard: B1: U2_P0_P0_0 B2: U2_P0_P0_1 System Rear Side PCIe Cable B3: PCIE3_PWR (Power Cable/Reseved) Slot 6: -- Motherboard: C1: U2_P0_P1_0 C2: U2_P0_P1_1 System Rear Side PCIe Cable C3: PCIE2_PWR (Power Cable/Reseved) Slot 10: --...
  • Page 47 CPU1 CPU0 Motherboard: D1: U2_P1_P0_0 D2: U2_P1_P0_1 System Rear Side PCIe Cable D3: PCIE4_PWR (Power Cable/Reseved) Slot 4: -- E1: U2_P1_P3_0 E2: U2_P1_P3_1 System Rear Side PCIe Cable E3: PCIE6_PWR (Power Cable/Reseved) Slot 7: -- F1: U2_P1_P2_0 F2: U2_P1_P2_1 System Rear Side PCIe Cable F3: PCIE6_PWR (Power Cable/Reseved) Slot 11: -- System Hardware Installation...
  • Page 48: Chapter 4 Motherboard Components

    Chapter 4 Motherboard Components Motherboard Components 32 31 CPU0 CPU1 Item Description 2 x 7 Pin ATX Backplane Power Connector 2 x 2 Pin P12V Backplane Power Connector 2 x 2 Pin P12V Backplane Power Connector 2 x 3 Pin Backplane Power Connector M.2 Slot (PCIe Gen3 x2, Supports NGFF-22110) M.2 Slot (PCIe Gen3 x4, Supports NGFF-22110) HDD Backplane Board Connector...
  • Page 49 Item Description TPM Module Connector (SPI Interface) IPMB Connector System Battery G-SC Module Connector OCP 3.0 Connector (PCIe Gen5 x16) Power Supply Connector#2 (Secondary) 2 x 4 Pin P12V GPU Power Connector 2 x 2 Pin Slot Power Connector 2 x 2 Pin Slot Power Connector 2 x 2 Pin Slot Power Connector MCIO Connector (U2_P1_P3_1) MCIO Connector (U2_P1_P2_0/U2_P1_P2_1)
  • Page 50: Jumper Settings

    Jumper Settings Clear CMOS CLR_CMOS Default Enable 1 2 3 BMC1 BMC2 BIOS2 BIOS1 NCSI Sw ch G-SC SW.1 NCSI_SW Onboard LAN CPU0 CPU1 Slot#2 OCP3.0 Slot#1 OCP3.0 HOST_SMBUS_SEL BIOS defined Reserved BIOS_PWD Clear supervisor password Normal [Default] BIOS_RCVR BIOS recovery mode Normal [Default] Motherboard Components - 50 -...
  • Page 51: G-Sc Module

    G-SC Module 4-3-1 CDCR114 BMC1 BMC2 BIOS2 BIOS1 Item Description 10/100/1000 Server Management LAN Port 1GbE LAN Port #2 1GbE LAN Port #1 USB 3.2 Gen1 Port x 2 Mini DP Port Motherboard Components - 51 -...
  • Page 52: Backplane Board Storage Connector

    Backplane Board Storage Connector 4-3-2 CBP2025 (Rear System Storage Board) Item Description MCIO 4i (SFF-TA1016/U_2_0) MCIO 4i (SFF-TA1016/U_2_1) SlimSAS 4i Connector (SFF-8654/SL_SAS0 Motherboard Components - 52 -...
  • Page 53: Chapter 2 Bios Setup

    Chapter 2 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 54  Main This setup page includes all the items of the standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 55: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 56 Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note1) BMC Firmware Version (Note1) Displays BMC firmware version information.
  • Page 57 Parameter Description Onboard LAN Information LAN1/LAN2 MAC Address (Note) Displays LAN MAC address information. System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format. (Note) The number of LAN ports listed will depend on the motherboard / system model. BIOS Setup - 57 -...
  • Page 58: Advanced Menu

    Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. When Boot Mode Select is set to UEFI (Default) BIOS Setup - 58 -...
  • Page 59 When "Boot Mode Select" is set to Legacy in the Boot > Boot Mode Select section BIOS Setup - 59 -...
  • Page 60: Trusted Computing

    5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be Security Device Support available. Options available: Disable, Enable. Default setting is Enable. Select Enable to activate TPM support feature. SPI TPM Support Options available: Disabled, Enabled.
  • Page 61: Psp Firmware Versions

    5-2-2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information. Items on this window are non-configurable. BIOS Setup - 61 -...
  • Page 62: Legacy Video Select

    5-2-3 Legacy Video Select Description Parameter Selects between onboard or external VGA support. OnBrd/Ext VGA Select Options available: Auto, Onboard, External. Default setting is Auto. This configurable option will be displayed when "Boot Mode Select" is set to Legacy in the Boot > (Note) Boot Mode Select section.
  • Page 63: Ast2600 Super Io Configuration

    5-2-4 AST2600 Super IO Configuration Description Parameter AST2600 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Press [Enter] for configuration of advanced items. Configuration BIOS Setup - 63 -...
  • Page 64 5-2-4-1 Serial Port 1 Configuration Description Parameter Serial Port 1 Configuration Enable/Disable the Serial Port (COM). When set to Enabled allows you to configure the Serial port 1 settings. When set to Disabled, displays no Serial Port (Note) configuration for the serial port. Options available: Disabled, Enabled.
  • Page 65: S5 Rtc Wake Settings

    5-2-5 S5 RTC Wake Settings Parameter Description Enable/Disable system wake on alarm event. Options available: Disabled, Fixed Time, Dynamic Time. When Fixed Time Wake System from S5 is selected, system will wake on the hr::min::sec specified. Default setting is Disabled. BIOS Setup - 65 -...
  • Page 66: Serial Port Console Redirection

    5-2-6 Serial Port Console Redirection Parameter Description Select whether to enable console redirection for specified device. Console COM1/Serial Over LAN redirection enables the users to manage the system from a remote Console Redirection (Note) location. Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items.
  • Page 67 Parameter Description Parity Š – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
  • Page 68 Parameter Description Legacy Console Redirection Press [Enter] to configure advanced items. Redirection COM Port Š – Selects a COM port for Legacy serial redirection. – Default setting is COM1/SOL. Resolution Š – Selects the number of rows and columns used in Console Redirection for legacy OS support.
  • Page 69 Parameter Description Flow Control Š – Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a 'stop' signal can Serial Port for Out-of-Band be sent to stop the data flow. Once the buffers are empty, a 'start' EMS Console Redirection signal can be sent to re-start the flow.
  • Page 70: Cpu Configuration

    5-2-7 CPU Configuration Description Parameter Enable/Disable the CPU Virtualization. SVM Mode Options available: Disabled, Enabled. Default setting is Enabled. Press [Enter] to view the memory information related to CPU 0/1. CPU 0/1 Information BIOS Setup - 70 -...
  • Page 71: Pci Subsystem Settings

    5-2-8 PCI Subsystem Settings BIOS Setup - 71 -...
  • Page 72 Description Parameter Displays the PCI Bus Driver version information. PCI Bus Driver Version Change MCIO PCIe lanes. U2_P0_P0/1/2, U2_P1_P0/2/3 Options available: Disabled, Auto, x8, x16, x4x4, x8x8, x8x4x4, Lanes (Note1) x4x4x8, x4x4x4x4. Default setting is Auto. When enabled, this setting will initialize the device expansion ROM U2_P0_P0/1/2, U2_P1_P0/2/3 for the related devices.
  • Page 73: Usb Configuration

    5-2-9 USB Configuration Parameter Description USB Configuration USB Module Version Displays the USB module version information. USB Controllers Displays the supported USB controllers. USB Devices: Displays the USB devices connected to the system. Enable/Disable the Legacy USB support function. AUTO option disables legacy support if no USB devices are connected.
  • Page 74 Parameter Description Selects the time-out value during a USB mass storage device reset. Device reset time-out Options available: 10 sec, 20 sec, 30 sec, 40 sec. Default setting is 20 sec. Maximum time the device will take before it properly reports itself to the Host Controller.
  • Page 75: Network Stack Configuration

    5-2-10 Network Stack Configuration Parameter Description Enable/Disable the UEFI network stack. Network Stack Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 PXE feature. Ipv4 PXE Support (Note) Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 HTTP feature. Ipv4 HTTP Support (Note) Options available: Enabled, Disabled.
  • Page 76: Post Report Configuration

    5-2-11 Post Report Configuration Parameter Description Post Report Configuration Error Message Report Enable/Disable the POST Error Message support. Post Error Message Options available: Enabled, Disabled. Default setting is Enabled. Halt On Options available: No Error, All Error. Default setting is No Error. BIOS Setup - 76 -...
  • Page 77: Nvme Configuration

    5-2-12 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system. Enable/Disable NVMe LED Control. NVMe LED Control Options available: System Default, Disabled, Enabled. Default setting is System Default. BIOS Setup - 77 -...
  • Page 78: Sata Configuration

    5-2-13 SATA Configuration Parameter Description Displays the installed HDD devices information. System will automatically SATA Configuration detect HDD type. BIOS Setup - 78 -...
  • Page 79: Graphic Output Configuration

    5-2-14 Graphic Output Configuration Parameter Description Selects output device type. Output Device Type Options available: First loaded Device, Onboard Device, External Device, Specific Device. Default setting is Onboard Device. BIOS Setup - 79 -...
  • Page 80: Amd Mem Configuration Status

    5-2-15 AMD Mem Configuration Status Description Parameter Press [Enter] to view the memory configuration status related to CPU 0/1. CPU 0/1 BIOS Setup - 80 -...
  • Page 81: Tls Auth Configuration

    5-2-16 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert Š – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
  • Page 82: Ram Disk Configuration

    5-2-17 RAM Disk Configuration Parameter Description Specifies the type of memory to use from available memory pool in system to create a disk. Disk Memory Type Options available: Boot Service Data, Reserved. Default setting is Boot Service Data. Creates a raw RAM disk. Size (Hex) Š...
  • Page 83: Iscsi Configuration

    5-2-18 iSCSI Configuration Parameter Description Press [Enter] and name iSCSI Initiator. Only IQN format is accepted. iSCSI Initiator Name Range: from 4 to 223 Add an Attempt Press [Enter] to configure advanced items. Delete Attempts Press [Enter] to configure advanced items. Change Attempt Order Press [Enter] to configure advanced items.
  • Page 84: Intel(R) I350 Gigabit Network Connection

    5-2-19 Intel(R) I350 Gigabit Network Connection BIOS Setup - 84 -...
  • Page 85 Description Parameter Press [Enter] to configure advanced items. Link Speed Š – Allows for automatic link speed adjustment. – Options available: Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, 100 Mbps Full. Default setting is Auto Negotiated. Wake On LAN NIC Configuration Š...
  • Page 86: Vlan Configuration

    5-2-20 VLAN Configuration Parameter Description Press [Enter] to configure advanced items. Create new VLAN Š VLAN ID Š – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
  • Page 87: Mac Ipv4 Network Configuration

    5-2-21 MAC IPv4 Network Configuration Parameter Description Indicates whether network address is configured successfully or not. Configured Options available: Enabled, Disabled. Default setting is Disabled. Options available: Enabled, Disabled. Default setting is Disabled. Enable DHCP (Note) Local IP Address Press [Enter] to configure local IP address. (Note) Press [Enter] to configure local NetMask.
  • Page 88: Mac Ipv6 Network Configuration

    5-2-22 MAC IPv6 Network Configuration Parameter Description Press [Enter] to configure advanced items. Displays the MAC Address information. Š Interface ID Š – The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3. DAD Transmit Count Š...
  • Page 89: Amd Cbs Menu

    AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU-related information that the BIOS automatically sets. Select a submenu item, then press [Enter] to access the related submenu screen. BIOS Setup - 89 -...
  • Page 90 5-3-1 CPU Common Options BIOS Setup - 90 -...
  • Page 91: Cpu Common Options

    Parameter Description CPU Common Options Performance Press [Enter] for configuration of advanced items. Allow REP-MOV/STOS to use non-caching streaming stores for large sizes. REP-MOV/STOS Streaming Options available: Disabled, Enabled. Default setting is Enabled. Prefetcher settings Press [Enter] for configuration of advanced items. Core Watchdog Press [Enter] for configuration of advanced items.
  • Page 92 Parameter Description Enable/Disable the PPIN feature. PPIN Opt-in Options available: Disabled, Enabled, Auto. Default setting is Auto. Enabled: Enter system memory is covered. SNP Memory (RMP Table) Options available: Disabled, Enabled, Custom, Auto. Coverage Default setting is Auto. Controls the Secure Memory Encryption Enable (SMEE) function. SMEE Options available: Disable, Enable, Auto.
  • Page 93 5-3-1-1 Performance Parameter Description Performance Options available: Normal Operation, Customized. Default setting is Normal OC Mode (Note) Operation. Allows you to accept or decline enabling Custom Core Pstates. When Custom Core Pstates accepted, you can disable or customize core pstates. Allows you to accept or decline enabling CCDs, processor cores and threads.
  • Page 94 5-3-1-2 Prefetcher Settings Parameter Description Prefetcher settings Enable/Disable L1 Stream HW Prefetcher. L1 Stream HW Prefetcher Options available: Disable, Enable, Auto. Default setting is Auto. Use memory access history of individual instructions to fetch additional lines when each access is a constant distance from the previous. L1 Stride Prefetcher Enable/Disable L1 Stride Prefetcher.
  • Page 95 5-3-1-3 Core Watchdog Parameter Description Core Watchdog Enable/Disable CPU Watchdog Timer. Core Watchdog Timer Enable (Note) Options available: Disabled, Enabled, Auto. Default setting is Auto. Select the CPU Watchdog Timer interval. Options available: 2.681s, 1.340s, 669.41ms, 334.05ms, 166.37ms, Core Watchdog Timer Interval 82.53ms, 40.61ms, 20.970ms, 10.484ms,5.241ms, 2.620ms, 1.309ms, 654.08us, 326.4us, 162.56us, 80.64us, 39.68us, Auto.
  • Page 96: Df Common Options

    5-3-2 DF Common Options Parameter Description DF Common Options Memory Addressing Press [Enter] for configuration of advanced items. ACPI Press [Enter] for configuration of advanced items. Link Press [Enter] for configuration of advanced items. SDCI Press [Enter] for configuration of advanced items. Probe Filter Press [Enter] for configuration of advanced items.
  • Page 97 5-3-2-1 Memory Addressing Parameter Description Memory Addressing Specifies the number of desired NUMA nodes per socket. Options available: NPS0, NPS1, NPS2, NPS4, Auto. Default setting is Auto. NUMA nodes per socket NOTE! • Available options may vary by system configuration. •...
  • Page 98 5-3-2-2 ACPI Parameter Description ACPI ACPI SRAT L3 Cache As Enable/Disable report each L3 cache as a NUMA Domain to the OS. Options available: Disabled, Enabled, Auto. Default setting is Auto. NUMA Domain Determines how the SLIT distances are declared. ACPI SLIT Distance Control Options available: Manual, Auto.
  • Page 99 5-3-2-3 Link Parameter Description Enable/Disable GMI link encryption. GMI encryption control Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable xGMI link encryption. xGMI encryption control Options available: Disabled, Enabled, Auto. Default setting is Auto. Configures the number of xGMI2 links used on a multi-socket system. xGMI Link Configuration Options available: Auto, 3 xGMI Links, 4 xGMI Links, 2 xGMI Links + 2 PCI Links.
  • Page 100 Parameter Description xGMI Global Preset List Press [Enter] to configure the xGMI Preset list. xGMI Initial Preset Press [Enter] to configure the xGMI Initial Preset CPU0/1 link. xGMI TXEQ Search Mask Press [Enter] to configure the xGMI TXEQ Search Mask CPU0/1 link. Press [Enter] to configure the xGMI AC/DC Coupled link.
  • Page 101 5-3-2-4 SDCI Parameter Description SDCI Options available: Disabled, Enabled, Auto. Default setting is Auto. (Note) DisRmSteer Options available: Disabled, Enabled, Auto. Default setting is Auto. (Note) Advanced items prompt when this item is defined. BIOS Setup - 101 -...
  • Page 102 5-3-2-5 Probe Filter Parameter Description Specifies whether multiple memory/CXL channels will share probe filter Organization storage. Options available: Auto, Dedicated, Shared. Default setting is Dedicated. Controls PDR settings that may impact performance by workload and/or Periodic Directory Rinse (PDR) processor. Tuning Options available: Memory-Sensitive, Cache-Bound, Neutral, Adaptive, Auto.
  • Page 103: Umc Common Options

    5-3-3 UMC Common Options Parameter Description UMC Common Options DDR Addressing Options Press [Enter] for configuration of advanced items. DDR Controller Configuration Press [Enter] for configuration of advanced items. DDR MBIST Options Press [Enter] for configuration of advanced items. DDR RAS Press [Enter] for configuration of advanced items.
  • Page 104 5-3-3-1 DDR Addressing Options Parameter Description DDR Addressing Options Interleaves memory blocks across the DRAM chip selects for node 0. Chipselect Interleaving Options available: Disabled, Auto. Default setting is Auto. Enable or disable bank addressing hashing. Address Hash Bank Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable or disable CS addressing hashing.
  • Page 105 5-3-3-2 DDR Controller Configuration Parameter Description DDR Controller Configuration DDR Power Options Press [Enter] for configuration of advanced items. Memory Channel Disable Press [Enter] for configuration of advanced items. Refresh Management (RFM) Press [Enter] for configuration of advanced items. BIOS Setup - 105 -...
  • Page 106 5-3-3-2-1 DDR Power Options Parameter Description DDR Power Options Enable or disable DDR power down mode. Power Down Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. Sub Urgent Refresh Lower Specifies the stored refresh limit required to enter sub-urgent refresh mode. Bound Urgent Refresh Limit Specifies the stored refresh limit required to enter urgent refresh mode.
  • Page 107 5-3-3-2-2 Memory Channel Disable Parameter Description Memory Channel Disable Memory Channel Disable Bitmask CPU0/1 Channel_# Press [Enter] to enable/disable specific memory channel. BIOS Setup - 107 -...
  • Page 108 5-3-3-2-3 Refresh Management (RFM) Parameter Description Refresh Management (RFM) Configure Refresh Management. Refresh Management Options available: Enable, Disable, Auto, Force Enable. Default setting is Auto. RAA Initial Management Override Rolling Accumulated ACT Initial Management Threshold. Options available: 32, 40, 48, 56, 64, 72, 80, Auto. Default setting is Auto. Threshold RAA Maximum Management Override Rolling Accumulated ACT Maximum Management Threshold.
  • Page 109 5-3-3-3 DDR MBIST Options Parameter Description DDR MBIST Options Enable/Disable the Memory MBIST function. MBIST Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. Selects MBIST Test Mode. Interface Mode: Tests Single and Multiple CS transactions and Basic Connectivity. MBIST Test Mode (Note1) Data Eye Mode: Measures Voltage vs.
  • Page 110 Parameter Description DDR Healing BIST Execution Options available: One Time, Every boot. Mode Default setting is One Time. (Note2) PMU Mem BIST Press [Enter] to enable/disable PMU Mem BIST Algorithm. Algorithm (Note2) For DRAM errors found in the BIOS memory BIST select the repair type. DDR Healing BIST Repair Options available: Soft Repair, Hard Repair, No Repairs -Test only.
  • Page 111 5-3-3-3-1 Data Eye Parameter Description Data Eye Pattern Select Options available: PRBS, SSO, Both. Default setting is PRBS. Pattern Length Determines the pattern length. The possible options are N=3..12. This item helps read the aggressors channels. Aggressor Channel Options available: One Sub-Channel, Half Channels, All Channels. Default setting is All Channels.
  • Page 112 Parameter Description Target Static Lane Select This item is configurable when Target Static Lane Control is set to Upper 32 bits Enabled. Target Static Lane Select This item is configurable when Target Static Lane Control is set to Lower 32 bits Enabled.
  • Page 113 5-3-3-4 DDR RAS Parameter Description DDR RAS Enable/Disable the Data Poisoning function. Data Poisoning Options available: Auto, Enabled, Disabled. Default setting is Auto. DRAM Boot Time Post Package Enable/Disable the DRAM Boot Time Post Package Repair function. Options available: Enable, Disable. Default setting is Disable. Repair DRAM Runtime Post Package Enable/Disable the DRAM Runtime Post Package Repair function.
  • Page 114 Parameter Description DRAM UECC Retry Š – Enable/Disable DRAM UECC Retry. – Options available: Auto, Enabled, Disabled. Default setting is Disabled. Max DRAM UECC Error Replay (Note) Š ECC Configuration – Default setting is 8. (continued) Memory Clear Š – Options available: Auto, Enabled, Disabled. Default setting is Auto.
  • Page 115 Parameter Description Configure DRAM Corrected Error Counter function. DRAM Corrected Error Counter Options available: Disable, NoLeakMode, LeakMode. Default setting is Enable LeakMode. Enable SMI when DRAM corrected Error Counter count exceeds the DRAM Corrected Error Counter threshold value. Interrupt Enable Options available: False, True.
  • Page 116 5-3-3-5 DDR Bus Configuration Parameter Description DDR Bus Configuration Select the DRAMs On-die Termination impedance for RTT_NOM_WR. Dram ODT impedance RTT_ Options available: Auto, RTT_OFF, RZQ (240), RZQ/2 (120), RZQ/3 (80) NOM_WR RZQ/4 (60), RZQ/5(48), RZQ/6(40), RZQ/7(34). Default setting is Auto. Select the DRAMs On-die Termination impedance for RTT_NOM_RD.
  • Page 117 Parameter Description Select the ODT impedance for all DBYTE IOs. Options available: Auto, High Impedance, 480 ohm, 240 ohm, 160 ohm, Processor ODT impedance 120 ohm, 96 ohm, 80 ohm, 68.6 ohm, 60 ohm, 53.3 ohm,48 ohm, 43.6 ohm, 40 ohm, 36.9 ohm, 34.3 ohm, 32 ohm, 30 ohm, 28.2 ohm, 26.7 ohm, 25.3 ohm.
  • Page 118 5-3-3-6 Enforce POR Parameter Description Enforce POR Decline/Accept to configure the advanced items. Accept Active Memory Timing Active memory Timing Settings. Options available: Auto, Enabled. Default setting is Auto. Settings (Note) Specifies the memory target speed in MT/s. Memory Target Speed Options available: Auto, DDR3200, DDR3600, DDR4000, DDR4400, DDR4800, DDR5200, DDR5600.
  • Page 119 5-3-3-7 DDR Training Options Parameter Description DDR Training Options Specify PDA enumeration mode. DRAM PDA Enumerate ID Options available: Auto, Toggling PDA enumeration mode, Legacy PDA Programming Mode enumeration mode. Default setting is Auto. BIOS Setup - 119 -...
  • Page 120 5-3-3-8 DDR Security Parameter Description Security Enable/Disable Transparent SME. TSME Options available: Auto, Enabled, Disabled. Default setting is Auto. Options available: AES-128, AES-256. Default setting is AES-256. Enable/Disable Data Scrambling. Data Scramble Options available: Enabled, Disabled. Default setting is Enabled. SME-MK Options available: Enabled, Disabled.
  • Page 121 5-3-3-9 DDR PMIC Configuration Parameter Description DDR PMIC Configuration Enables support for PMIC Error Reporting. PMIC Error Reporting Options available: Auto, False, True. Default setting is Auto. Options available: Secure Mode, Programmable Mode. PMIC Operation Mode Default setting is Programmable Mode. Options available: Always, Never, Once.
  • Page 122 5-3-3-10 DDR Miscellaneous Parameter Description DDR Miscellaneous DRAM Survives Warm Reset Options available: Enabled, Disabled. Default setting is Disabled. ODTS CMD Throttle Threshold Options available: Auto, > 85'C, > 90'C, > 95'C. Default setting is Auto. BIOS Setup - 122 -...
  • Page 123 5-3-3-11 DDR PHY (CMN) Parameter Description DDR PHY (CMN) Periodic Training Options available: Auto, Enabled, Disabled. Default setting is Auto. (Note) Periodic Training Interval Specifies the Periodic Training interval in millisecond. (Note) Advanced items prompt when this item is defined. BIOS Setup - 123 -...
  • Page 124: Nbio Common Options

    5-3-4 NBIO Common Options BIOS Setup - 124 -...
  • Page 125 Parameter Description NBIO Common Options Enable/Disable the IOMMU function. IOMMU Options available: Disabled, Enabled. Default setting is Enabled. Enable/Disable DMAr system protection during POST. DMAr Support Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable DMA remap support in IVRS IVinfo Field. DMA Protection Options available: Auto, Enabled, Disabled.
  • Page 126 Parameter Description Enable/Disable the data link feature capability. Data Link Feature Cap Options available: Enabled, Disabled, Auto. Default setting is Auto. Enable/Disable the running PCIE CV tool support. CV test Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the SEV-SNP support. SEV-SNP Support Options available: Disable, Enable.
  • Page 127 5-3-4-1 SMU Common Options Parameter Description SMU Common Options Power Policy Quick Options available: Standard, Best Performance, Energy Efficient. Setting Default setting is Standard. TDP Control Options available: Manual, Auto. Default setting is Auto. PPT Control Options available: Manual, Auto. Default setting is Auto. Selects use the fused Determinism or set customized Determinism.
  • Page 128 Parameter Description Enable/Disable the CPPC feature. CPPC Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable the HSMP support. HSMP Support Options available: Disabled, Enabled, Auto. Default setting is Auto. SVI3 SVC Speed Control Options available: Auto, Manual. Default setting is Auto. Options available: Auto, Disable, 1 stack, 2 stack, 4 stack.
  • Page 129 5-3-4-2 NBIO RAS Common Options Parameter Description NBIO RAS Common Options NBIO RAS Control Options available: Disabled, MCA, Auto. Default setting is Auto. Configures the Egress Poison High Severity. Each bit set to 1 enables Egress Poison Severity High High severity on the associated IOHC egress port. A bit of 0 indicates LOW severity.
  • Page 130 Parameter Description Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enable Mask High arrays. Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enable Mask Low arrays. Specifies the timer interval of the SYSHUB Watchdog timer in System Hub Watchdog Timer milliseconds.
  • Page 131 5-3-4-3 nBif Common Options Parameter Description SRIOV Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. Š – Options available: Auto/Default, Disabled, Enabled. Default setting is Auto/Default. Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. Š...
  • Page 132 Parameter Description SDXI Class Code Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. MPDMA-TF PASID Control Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. (continued) ATOMICOP_REQUEST Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. ACS Rcc_Dev0 Š...
  • Page 133 Parameter Description P2PEgress ACS Control Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. P2pReqStrap5 Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. RCC_DEV0 E2E_PREFIX Š (continued) – Options available: Auto, Disabled, Enabled. Default setting is Auto. EXTENDED_FMT Š...
  • Page 134 5-3-4-4 Link EQ Preset Options Parameter Description Press [Enter] to configure advanced items. GEN3/4/5 Preset Search Mask Configuration Š – Options available: Custom, Auto. Default setting is Auto. BIOS Setup - 134 -...
  • Page 135: Fch Common Options

    5-3-5 FCH Common Options Parameter Description FCH Common Options I3C/I2C Configuration Options Press [Enter] for configuration of advanced items. SATA Configuration Options Press [Enter] for configuration of advanced items. USB Configuration Options Press [Enter] for configuration of advanced items. AC Power Loss Options Press [Enter] for configuration of advanced items.
  • Page 136 5-3-5-1 I3C/I2C Configuration Options Parameter Description I3C/I2C Configuration Options Options available: Both Disabled, I3C Enabled, I2C Enabled, Auto. I3C/I2C 0/1/2/3 Enable Default setting is Auto. I2C 4/5 Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. Release SPD Host Control Options available: Disabled, Enabled.
  • Page 137 5-3-5-2 SATA Configuration Options Parameter Description SATA Configuration Options Enable/Disable OnChip SATA controller. SATA Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA RAS Support Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA Staggered Spin-up Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA Disabled AHCI Prefetch Options available: Disabled, Enabled, Auto.
  • Page 138 5-3-5-3 USB Configuration Options Parameter Description USB Configuration Options Enable/Disable USB controller. XHCI Controller0/1 enable Options available: Enabled, Disabled, Auto. Default setting is Auto. USB ecc SMI Enable Options available: Enable, Off, Auto. Default setting is Auto. Press [Enter] for configuration of advanced items. MCM USB enable XHCI2/ XHCI3 enable (Socket1) Š...
  • Page 139 5-3-5-4 AC Power Loss Options Parameter Description AC Power Loss Options Selects the AC Loss Control Method. AC Loss Control Options available: Power Off, Power On, Last State. Default setting is Last State. BIOS Setup - 139 -...
  • Page 140 5-3-5-5 Uart Configuration Options Parameter Description Uart Configuration Options Uart 0/1/2/3 Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 140 -...
  • Page 141 5-3-5-6 ESPI Configuration Options Parameter Description ESPI Configuration Options ESPI Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 141 -...
  • Page 142 5-3-5-7 FCH RAS Options Parameter Description FCH RAS Options Enable/Disable the ALink RAS Support. ALink RAS Support Options available: Disabled, Enabled, Auto. Default setting is Auto. Enables AB to forward downstream sync-flood message to system Reset After Sync-Flood controller. Options available: Enable, Disable, Auto. Default setting is Auto. BIOS Setup - 142 -...
  • Page 143 5-3-5-8 Miscellaneous Options Parameter Description Miscellaneous Options Enable/Disable Boot Timer. Boot Timer Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 143 -...
  • Page 144: Soc Miscellaneous Control

    5-3-6 SOC Miscellaneous Control Parameter Description SOC Miscellaneous Control Enable/Disable the ConsoleOut function for ABL. ABL Console Out Control (Note) Options available: Disable, Enable, Auto. Default setting is Auto. ABL Console Out Serial Options available: eSPI, SOC UART0, SOC UART1, Auto. Default setting is Auto.
  • Page 145 Parameter Description Press [Enter] for configuration of advanced items. FAR enforcement state Š – Default setting is Enabled. Firmware Anti-rollback (FAR) SPL value in the CPU Fuse Š SPL value in the SPL table Š FAR Switch Š – Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 145 -...
  • Page 146: Cxl Common Options

    5-3-7 CXL Common Options Parameter Description CXL Common Options CXL Control Options available: Auto, Enabled, Disabled. Default setting is Auto. Options available: Auto, Enabled, Disabled. Default setting is Auto. CXL SPM CXL Encryption Options available: Enabled, Disabled. Default setting is Disabled. Options available: Auto, Enabled, Disabled.
  • Page 147: Amd Pbs Menu

    AMD PBS Menu AMD PBS Option menu displays submenu options for configuring the function of AMD PBS. Select a submenu item, then press [Enter] to access the related submenu screen. Parameter Description Press [Enter] for configuration of advanced items. Enable/Disable SPI Locking for protect ROM part. SPI Locking Options available: Disabled, Enabled.
  • Page 148: Ras

    5-4-1 RAS Parameter Description Enable/Disable the Periodic SMI for polling [MCA Threshold] error. RAS Periodic SMI Control Options available: Disabled, Enabled. Default setting is Enabled. SMI Threshold Configures the SMI Threshold value. SMI Scale Configures the SMI Scale value. Defines the unit of time scale. SMI Scale Unit Options available: millisecond, second, minute.
  • Page 149 Parameter Description PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Mask register of Root Port. Mask Reg PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Severity register of Root Port. Sev Reg PCIe Device Corr Err Mask Initialize the PCIe AER Corrected Error Mask register of PCIe device.
  • Page 150: Chipset Setup Menu

    Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of the North Bridge. Select a submenu item, then press <Enter> to access the related submenu screen. Parameter Description PCIe Compliance Mode Options available: Off, On. Default setting is Off. Enable/Disable program all VR on MB.
  • Page 151: North Bridge

    5-5-1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information. CPU 0/1 Information Press [Enter] to view information related to CPU 0/1. BIOS Setup - 151 -...
  • Page 152 5-5-2 Fabric Resource BIOS Setup - 152 -...
  • Page 153: Fabric Resource

    Parameter Description Fabric Resource CPU 0/1 NBIO_# PCIe Bus Change CPU 0/1 NBIO_# PCIe Bus Number. Number Change CPU 0/1 NBIO_# Prefetchable MMIO Above 4G Size. Prefetchable Mmio Above 4G Options available: System Default, 0, 1G, 2G, 4G, 8G, 16G, 32G, 64G, size 128G, 256G, 512G, 1T, 2T, 4T, 8T.
  • Page 154: Server Management Menu

    Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Default setting is Enabled. FRB-2 Timer Configures the FRB-2 Timer timeout. timeout Default setting is 20 minutes. Configures the FRB-2 Timer policy. FRB-2 Timer Policy Options available: Do Nothing, Reset, Power Down, Power Cycle. Default setting is Do Nothing.
  • Page 155 Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC network Press [Enter] to configure advanced items. configuration IPv6 BMC Network Press [Enter] to configure advanced items. Configuration BIOS Setup - 155 -...
  • Page 156: System Event Log

    5-6-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Disabled, Enabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Erase SEL Options available: No/Yes, On next reset/Yes, On every reset.
  • Page 157: View Fru Information

    5-6-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 157 -...
  • Page 158: Bmc Network Configuration

    5-6-3 BMC Network Configuration Parameter Description BMC network configuration Lan Channel 1 Selects to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters Configuration Address source during BIOS phase. Options available: Unspecified, Static, DynamicBmcDhcp. Default setting is DynamicBmcDhcp.
  • Page 159: Ipv6 Bmc Network Configuration

    5-6-4 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
  • Page 160: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 161: Secure Boot

    5-7-1 Secure Boot The Secure Boot submenu is applicable when your device is installed the Windows 8 (or above) operating ® system. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function. Secure Boot Options available: Enabled, Disabled.
  • Page 162 Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision Š – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
  • Page 163: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
  • Page 164 Parameter Description FIXED BOOT ORDER Priorities Press [Enter] to configure the boot priority. By default, the server searches for boot devices in the following sequence: Hard drive. Boot Option #1 / #2 / #3 / #4 / #5 CD-COM/DVD drive. USB device.
  • Page 165: Save & Exit Menu

    Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save Changes and Exit Options available: Yes, No.
  • Page 166: Bios Recovery

    5-10 BIOS Recovery The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: 1.
  • Page 167: Bios Post Beep Code (Ami Standard)

    5-11 BIOS POST Beep code (AMI standard) 5-11-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...

This manual is also suitable for:

E283-z91-aav1

Table of Contents