Download Print this page

Telex ALP-600 Instruction Manual

Uhf log periodic antenna

Advertisement

Quick Links

TELEX COMMUNICATIONS, INC.
8601 East Cornhusker High way, P.O. Box 5579, Lin coln NE 68505
IN STRUC TION MAN UAL
Gen eral De scrip tion
The ALP-600 is a broad band bi-directional log pe -
ri odic an tenna. It will re ceive any fre quency from
520 to 760 MHz. The "gain" of this an tenna en ables
it to re ceive sig nals from a greater dis tance than a
typ i cal "whip" type an tenna.
Gain ..................................................................................................................1.6 dBd
1/2 Power Beam Width .........................................................................................120°
Front-to-Back Ra tio...........................................................................................19.4 dB
SWR.......................................................................................................................1.5:1
In put Im ped ance ................................................................................................50 ohm
In put Con nec tor ....................................................................................................TNC
Size............................................................................12" (304.8mm) x 17" (431.8mm)
An tenna Place ment
The ALP-600 should be placed in a po si tion that
has a clear view of the trans mit ter(s) for best re -
sults. Ob struc tions such as walls, ceil ings, and
metal ob jects will re duce range and per for mance.
An tenna Mount ing
The ALP-600 is sup plied with hard ware for tu bu lar
clamp ing. It should al ways be mounted ver ti cally
with the ground and per pen dic u lar to the trans mit -
ter(s), See Fig ure 1.
ALP-600
R
UHF Log Pe ri odic An tenna
Or der No. 878896
Log Pe ri odic An tennas are also di rec tional and
will have the best re cep tion when pointed at the
trans mit ter. This yields the ben e fit of less in ter fer -
ence from un wanted sig nals com ing from the back
or side of the an tenna.
SPEC I FI CA TIONS
(av er age)
-1-
801542
T
elex
TR-600
Fig ure 1

Advertisement

loading

Summary of Contents for Telex ALP-600

  • Page 1 An tenna Mount ing The ALP-600 is sup plied with hard ware for tu bu lar clamp ing. It should al ways be mounted ver ti cally with the ground and per pen dic u lar to the trans mit - ter(s), See Fig ure 1.
  • Page 2 Mount ing Sug ges tions Fig ure 2 ALP-600 An tenna Mast ALP-600 FOOTBALL TR-600's FIELD COACHES BOX Refer to Figure 4 for typical antenna pattern. Fig ure 3 Top View of Field...
  • Page 3 ALP-600 An tenna Pat tern Fig ure 4 Typ i cal ALP-600 UHF Bi-Directional An tenna Pat tern...
  • Page 4 Clamps Clamps are pro vided for mount ing the ALP-600 onto the an tenna mast. At tach the clamps with the hard ware sup plied. See Fig ure 5. Coax Ca ble For best re sults, it is rec om mended that ca ble losses be kept un der 4 dB.

This manual is also suitable for:

878896