Polaris Sportsman 570 Owner's Manual For Maintenance And Safety page 60

Hide thumbs Also See for Sportsman 570:
Table of Contents

Advertisement

FEATURES AND CONTROLS
Instrument Cluster
Diagnostic Display Code Definitions
Component
Fan Relay Driver
Circuit
Ignition Coil Primary
Driver 1 (Front)
(MAG)
Fuel Pump Driver
Circuit
Oxygen Sensor 1
ECU Output Supply
Voltage 1
ECU Output Supply
Voltage 2
ECU Output Supply
Voltage 3
ETC Accelerator
Position Sensor
Outputs 1 & 2
Correlation
58
Diagnostic Codes
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Current Below Normal Or Open Circuit
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Current Below Normal Or Open Circuit
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Current Below Normal Or Open Circuit
Data Erratic, Intermittent Or Incorrect
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Bad Intelligent Device Or Component
Data Valid But Above Normal Operational Range - Most
Severe Level
Data Valid But Below Normal Operational Range - Most
Severe Level
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Data Valid But Above Normal Operating Range - Moderately
Severe Level
Data Valid But Below Normal Operating Range - Moderately
Severe Level
Data Valid But Above Normal Operational Range - Most
Severe Level
Data Valid But Below Normal Operational Range - Most
Severe Level
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Data Valid But Above Normal Operating Range - Moderately
Severe Level
Data Valid But Below Normal Operating Range - Moderately
Severe Level
Data Valid But Above Normal Operational Range - Most
Severe Level
Data Valid But Below Normal Operational Range - Most
Severe Level
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Data Valid But Above Normal Operating Range - Moderately
Severe Level
Data Valid But Below Normal Operating Range - Moderately
Severe Level
Data Erratic, Intermittent Or Incorrect
Condition
SPN
FMI
1071
3
1071
4
1071
5
1268
3
1268
4
1268
5
1347
3
1347
4
1347
5
3056
2
3056
3
3056
4
3056
12
3597
0
3597
1
3597
3
3597
4
3597
16
3597
18
3598
0
3598
1
3598
3
3598
4
3598
16
3598
18
3599
0
3599
1
3599
3
3599
4
3599
16
3599
18
65613
2