Temperature problem

Fault
The set temperature is not
reached.
Fully automatic defrosting
no longer works.
Cause
The freezer compartment
door was open for a long
time. The evaporator (refri-
geration unit) in the noFrost
system is heavily iced up.
Troubleshooting en
troubleshooting
Requirement: Store the frozen food
well insulated in a cool place.
"Switch off the appliance."
1.
→ Page 16
Disconnect the appliance from the
2.
mains.
Unplug the appliance from the
mains or switch off the circuit
breaker in the fuse box.
Move the appliance away from the
3.
wall.
Leave the appliance door open.
4.
a After approx. 20 minutes, the con-
densation starts to run into the
evaporation pan at the rear of the
appliance.
To prevent the evaporation pan
5.
from overflowing, mop up the con-
densation water with a sponge.
The evaporator is defrosted if no
more condensation water runs into
the evaporation pan.
"Clean the interior of the appliance."
6.
→ Page 21
"Switch the appliance back on."
7.
→ Page 16