Installation Dimension; Installing The Unit; Installing The Wall Hook Bracket - Fujitsu AirStage AS A004GTEH Series Installation Manual

Hide thumbs Also See for AirStage AS A004GTEH Series:
Table of Contents

Advertisement

3.2. Installation dimension

004/007/009 model
80 mm or
more (*1)
Left side
70 mm or
more (*2)
1500 mm
or more
030/034 model
Left side
80 mm or
70 mm or more
more (*1)
(*2)
1500 mm or more
1800 mm or
more
*1: The distance between the wall hook bracket and the ceiling.
*2: The distance between the wall hook bracket and the side wall.

3.3. Installing the unit

Install the air conditioner in a location which can withstand a load of at least 5 times the
weight of the main unit and which will not amplify sound or vibration. If the installation
location is not strong enough, the indoor unit may fall and cause injuries.
If the job is done with the panel frame only, there is a risk that the unit will come loose.
Please take care.
3.3.1. Determining the piping direction
The piping can be connected
according to the figure and table.
When the piping is connected
in direction (B), (C), (D) or (E),
cut along the piping groove in
the side of the front panel with a
hacksaw.
Model
(A)
(B)
Rear
Right
outlet
outlet
004/007/009
Good
Good
030/034
Good
Good

4. INSTALLING THE WALL HOOK BRACKET

• Refer to figure below for the installation hole dimensions of the wall hook bracket.
• Before fastening the wall hook bracket to the wall with the screws, level it by tapping the
hook at the center of bracket to the wall with the handle of a screwdriver.
(1) Fasten the wall hook bracket to the wall with 5 or more screws and anchor bolts
through the holes near the outer edge of the bracket.
(Do not install the wall hook bracket at only 1 place or at an angle.)
(2) For a concrete wall, embed anchor bolts (10 mm dia.) into the wall at the wall hook
bracket holes.
(Allow the anchor bolts to stick out at least 18 mm from the wall. Use 2 bolts for flat
concrete wall and 4 bolts for blister concrete wall.)
(3) Install the nuts to the anchor bolts through the wall hook bracket.
(4) Finally tighten the bolts and wood screws after confirming, using the level indicator,
that the clamp is horizontal.
Install the wall hook bracket level, both horizontally and vertically. If the wall hook
bracket is tilted, wa ter will drip to the floor.
As the weight of the indoor unit is 15 to 18 kg, it should be installed after properly exam-
ining the place where it is in tended to be in stalled. If the place is not strong enough, a
plank or girder should be used to make the place sufficiently strong so that the wall can
support the weight.
En-3
Wall hook bracket
Right side
200 mm or
more (*2)
1800 mm or
Wall cap
more
Wall hook bracket
Right side 200
mm or more (*2)
Wall cap
WARNING
(B)
(A)
(C)
(C)
(D)
(E)
(F)
Bottom
Left
Left
Center
outlet
bottom
outlet
outlet
outlet
Good
Good
Good
Good
Good
Good
Good
WARNING
004/007/009 model
030/034 model
4.3.1. Cutting the hole in the wall for the connecting piping
(1) Cut a hole in the wall at the position shown in the following.
(2) Cut the hole so that the outside end is lower (5 to 10 mm) than the inside end.
(3) Always align the center of the wall hole. If misaligned, water leakage will occur.
(4) Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap
with vinyl tape, and stick the pipe through the hole.
(5) For left piping and right piping, cut the hole a little lower so that drain water will flow
freely.
004/007/009 model
030/034 model
(E)
(G)
Lower
(F)
(D)
(G)
Left rear
outlet
Attach the wall pipe
Good
Good
If the wall pipe is not used, the
cable interconnecting the indoor
and outdoor units may touch
metal and cause electric leakage.
4.3.2. Attach the drain hose insulation (030/034 model only)
• Wrap the insulation around the
drain hose, making sure that
there are no gaps.
• Attach the Insulation (Drain
hose) to the drain hose.
Wall hook bracket
Tapping screw
(accessory, 5 pcs)
Wall hook bracket
Wall hook bracket
Center mark
65 mm dia. hole
Wall hook bracket
80 mm dia. hole
80 mm dia. hole
10 mm
or more
Fasten with vinyl
tape
WARNING
Wall cap*
Tapping screw
(accessory, 8 pcs)
Center mark
65 mm dia. hole
Center mark
Lower
10 mm
or more
5 to 10 mm
low
Wall pipe*
* Locally
purchased
(Inside)
Wall
(Outside)
Insulation (Drain hose)
(Accessories)
Drain hose

Advertisement

Table of Contents
loading

Table of Contents