Power Supply Fail Header; Power Supply Fail Alarm Reset Header - Supero SuperServer 7042S-i User Manual

Supermicro superserver 7042s-i servers: user guide
Table of Contents

Advertisement

Power Supply Fail Header

Connect a cable from your power
supply to the JP13 header to pro-
vide warning of power supply fail-
ure. The warning signal is passed
through the Power Fail LED pin on
JF1 to provide indication of a
power failure on the chassis.
Note: This feature is only avail-
able when using triple redundant
Supermicro power supplies.
the table on the right for pin defini-
tions.
Power Supply Fail Alarm
Reset Header
Connect a cable from your power
supply to the JP23 header to pro-
vide you with a reset switch for
the power supply fail alarm.
Note: This feature is only avail-
able when using triple redundant
Supermicro power supplies.
Chapter 5: Advanced Motherboard Setup
P o w e r S u p p ly F a il H e a d e r
P in
N um ber
See
5-17
P in D e fin itio n s (J P 1 3 )
D efinition
1
P /S 1 Fail S ignal
2
P /S 2 Fail S ignal
3
P /S 3 Fail S ignal
4
R es et (from M B )

Advertisement

Table of Contents
loading

Table of Contents