Unit Low Voltage Wiring
A
XC13
XC13
NOTE - Refer to furnace, blower coil and accessory instructions for additional wiring configurations with other
optional controls.
C
WIRE NUTS
CUTOUT WITH
GROMMET
24V CONTROL WIRES
B
24VAC Control Wiring Diagrams (Field-Installed)
XC13
WIRE RUN LENGTH
LESS THAN 100' (30 METERS)
MORE THAN 100' (30 METERS)
A
Run 24VAC control wires through cutout with grommet.
B
Run 24VAC control wires through wire tie.
C
Make 24VAC control wire connections using field provided wire
nuts.
D
Tighten wire tie to security 24V control wiring.
NOTE - FOR PROPER VOLTAGES, SELECT THERMOSTAT WIRE (CONTROL WIRES)
GAUGE PER TABLE ABOVE.
NOTE - WIRE TIE PROVIDES LOW VOLTAGE WIRE STRAIN RELIEF AND MAINTAINS
SEPARATION OF FIELD-INSTALLED LOW AND HIGH VOLTAGE CIRCUITS.
NOTE - DO NOT BUNDLE ANY EXCESS 24VAC CONTROL WIRES INSIDE CONTROL
BOX.
D
TIGHTEN WIRE TIE
FIGURE 12
XC13
XC13
FIGURE 13
Page 12
HIGH VOLTAGE FIELD WIRING
FACTORY WIRING
LOW VOLTAGE (24V) FIELD WIRING
AWG# INSULATION TYPE
18
TEMPERATURE RATING
16
35ºC MINIMUM.