Contactor
Contactor operation is achieved by energizing an operating coil in response to a call for heat from the immersion
thermostat. Upon a call for heat, one or more contactors will energize all heating elements simultaneously. The
operating coils are voltage specific, When contactor replacement is required be sure to order the proper operating coil
base on the voltage rating found on the rating plate located on the front of the water heater.
Te r m i n a l c o n n e c ti o n s to th e
f u se bl oc k an d/ or t e r m i n a l bl o c k
Terminal connections to the
heating elements
Direct Immersion "Screw-in" Type Heating Element
8
1-½" Hex
Screw-in Flange
Terminal Block
Screw
GENERAL INFORMATION
Terminal Block
Zinc Plated Copper or
Incoloy Sheath
Element Rating Ink Stamped
on side of Terminal Block.
Page 8
Terminal connections of
contactor operating coil.