10-2-14 DC_link voltage sensor error
Indoor display
3-LED DISPLAY
LED1
LED2
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Is the input voltage of outdoor terminal block is normal?
2) Is the reactor wire connected?
2. Troubleshooting procedure
Is the connected of reactor wire?
Start the operation (cooling mode or heating mode)
voltage ("CE101,CE102,CE103" ) is normal in oper
Normal range(280Vdc~320Vdc)
sensing voltage("R101") is normal in operation mode?
Normal range (0.2Vdc~4.8Vdc)
Is the reactor insulation damaged?
10-16
LED3
LED OFF
(PBA-Reactor)
YES
Rest
Is the DC_link
at
ion mode?
YES
Is the DC_link
YES
YES
Exchange the Reactor
7-SEG DISPLAY
E469
DC_link voltage sensor error
NO
Connect the reactor wire
NO
Check the power input
NO
Exchange the Outdoor PBA
NO
Exchange the Outdoor PBA