Introduction
This document explains how to set motor limits (end positions) and how to connect the low voltage data cables
to an M50Q series motor. Refer to the M50Q 230VAC Specifications document for technical details.
Products
M50Q 230VAC 50Hz series motors — M50Q 326B, M50Q 626B, M50Q 1530B
NOTE: M50Q part numbers ending with "A" are 120VAC and those ending with "B" are 230VAC.
Before You Start
 On power-up: LEDs will blink RED YELLOW
 CW is clockwise rotation looking at the motor from the head end, CCW is counterclockwise.
 Be sure the motor is connected to continuous AC power.
 An M50Q series motor ships from the factory with a randomized RQ address between C00 and ZZZ and no
limits set.
 The M50Q series motor has a 3-conductor, keyed AC power connection in the motor head for connecting the
included AC power cord, PC M40/50 UNIV.
 The M50Q series motor has a 5-conductor, keyed low voltage, data connection (RQ Bus and RP Bus) for
use with the CBL 6 FT QE QM, CBL 1 FT QE QM, or RE 1 FT QM, each sold separately. This cable must be
connected after the AC power connection is in place and AC power is applied.
 The M50Q series motor has a 3-conductor, keyed low voltage, manual input (dry contact) connection for use
with CBL 6 FT DM, sold separately. This cable must be connected after the AC power connection is in place
and AC power is applied.
 The M50Q series motor has three clear buttons with internal LEDs:
o
Button 1, RED LED button, with one groove, operates the motor counterclockwise [CCW].
o
Button 2, GREEN LED button, with two grooves, operates the motor clockwise [CW].
o
Center Button, YELLOW LED button with no groove, used to set and clear motor options.
 If any button is pressed while the motor is moving, the motor will stop.
 Use an SP1E3Q when connecting more than two RQ-enabled motors (M40Q or M50Q).
 Refer to the M40Q and M50Q Typical Wiring Diagram on page 4 for an example of wiring.
January 2013, rev A
M50Q 230VAC series, v4.5
Motor
Quick Setup
© 2013 Electronic Solutions, Inc.
Electronic Solutions, Inc.
1355 Horizon Avenue
Lafayette, CO 80026 U.S.A.
www.elec-solutions.com
Tel: (303) 469-9322
Page 1 of 4

Advertisement

loading

Summary of Contents for ESI M50Q 230VAC Series

  • Page 1 Electronic Solutions, Inc. M50Q 230VAC series, v4.5 1355 Horizon Avenue Lafayette, CO 80026 U.S.A. Motor www.elec-solutions.com Quick Setup Tel: (303) 469-9322 Introduction This document explains how to set motor limits (end positions) and how to connect the low voltage data cables to an M50Q series motor.
  • Page 2 M50Q 230VAC series Motor Quick Setup v4.5 Power-Up the M50Q The M50Q series motor includes a keyed 3-conductor AC power connection in the head end of the motor.  Securely connect the included AC Power Cord (PC M40/50 UNIV) to this connector. Installer shall connect appropriate AC power plug to blunt-cut end.
  • Page 3 M50Q 230VAC series Motor Quick Setup v4.5  Toggle Motor Direction: 1. Simultaneously press and hold both Button 1 (CCW) and Button 2 (CW), until both the RED and GREEN LEDs light (approx. 5 seconds) then release both buttons. 2. If motor direction is such that the Open command is CW, then the LEDs will blink RED then GREEN. If motor direction is such that the Open command is CCW, then the LEDs will blink GREEN then RED.
  • Page 4 M50Q 230VAC series Motor Quick Setup v4.5 M40Q and M50Q Typical Wiring Diagram Connect to appropriately Connect to appropriately grounded AC Power with grounded AC Power with Branch Circuit Protection Branch Circuit Protection SP1E3QB M50Q M50Q To Optional Input Device...

This manual is also suitable for:

M50q 326bM50q 626bM50q 1530b