This document explains how to set motor limits (end positions) and how to connect the low voltage data
cables to an M50Q series motor. Refer to the M50Q 120VAC Specifications document for technical details.
Products
M50Q 120VAC 60Hz series motors — M50Q 330A, M50Q 634A, M50Q 1234A
NOTE: M50Q part numbers ending with "A" are 120VAC and those ending with "B" are 230VAC.
Before You Start
 On power-up: LEDs will blink RED GREEN
 CW is clockwise rotation looking at the motor from the head end, CCW is counterclockwise.
 Be sure the motor is connected to continuous AC power.
 An M50Q series motor ships from the factory with a randomized RQ address between C00 and ZZZ and
no limits set.
 The M50Q series motor has a 3-conductor, keyed AC power connection in the motor head for connecting
the included AC power cord, PC M40/50 US.
 The M50Q series motor has a 6-conductor, keyed low voltage, data connection (RQ Bus and RP Bus) for
use with the CBL 6 FT QE QM, CBL 1 FT QE QM, or RE 1 FT QM, each sold separately. This cable must
be connected after the AC power connection is in place and AC power is applied.
 The M50Q series motor has a 3-conductor, keyed low voltage, manual input (dry contact) connection for
use with CBL 6 FT DM, sold separately. This cable must be connected after the AC power connection is in
place and AC power is applied.
 The M50Q series motor has three clear buttons with internal LEDs:
o
Button 1, RED LED button, with one groove, operates the motor counterclockwise [CCW].
o
Button 2, GREEN LED button, with two grooves, operates the motor clockwise [CW].
o
Center Button, YELLOW LED button with no groove, used to set and clear motor options.
 If any button is pressed while the motor is moving, the motor will stop.
 Use an SP1E3Q when connecting more than two RQ-enabled motors (M40Q or M50Q).
 Refer to the M40Q and M50Q Typical Wiring Diagram on page 4 for an example of wiring.
November 2012, rev B
M50Q 120VAC series, v4.0
Motor
Quick Setup
© 2012 Electronic Solutions, Inc.
Electronic Solutions, Inc.
1355 Horizon Avenue
Lafayette, CO 80026 U.S.A.
www.elec-solutions.com
Tel: (303) 469-9322
Page 1 of 4

Advertisement

loading

Summary of Contents for ESI M50Q Series

  • Page 1  CW is clockwise rotation looking at the motor from the head end, CCW is counterclockwise.  Be sure the motor is connected to continuous AC power.  An M50Q series motor ships from the factory with a randomized RQ address between C00 and ZZZ and no limits set.
  • Page 2 Quick Setup v4.0 Power-Up the M50Q The M50Q series motor includes a keyed 3-conductor AC power connection in the head end of the motor.  Securely connect the included AC Power Cord (PC M40/50 US) to this connector. Motor Configuration ...
  • Page 3 M50Q 120VAC series Motor Quick Setup v4.0  Toggle Motor Direction: 1. Simultaneously press and hold both Button 1 (CCW) and Button 2 (CW), until both the RED and GREEN LEDs light (approx. 5 seconds) then release both buttons. 2. If motor direction is such that the Open command is CW, then the LEDs will blink RED then GREEN. If motor direction is such that the Open command is CCW, then the LEDs will blink GREEN then RED.
  • Page 4 M50Q 120VAC series Motor Quick Setup v4.0 www.elec-solutions.com © 2012 Electronic Solutions, Inc. Page 4 of 4...

This manual is also suitable for:

M50q 330aM50q 634aM50q 1234a