Fujitsu AOU36RLAVS4 Installation Manual page 13

Table of Contents

Advertisement

Normal mode
Heating capacity
Save energy mode
shift (*1)
12
High power mode 1
High power mode 2
Set this item when necessary.
13
Prohibited (Factory default)
14
Prohibited (Factory default)
16
Prohibited (Factory default)
Standard
Prohibited
Height difference
Height difference
between indoor
units
Prohibited
17
Prohibited
If installing the indoor units (even only one set) to a lower floor than the outdoor unit, and
the height difference between the indoor units is 119 in (3 m) or greater (i.e., if installing
the indoor units on separate floors), set "02 (height difference)".
18
Prohibited (Factory default)
Normal mode
On: 35.6°F (2°C)
Base pan heater
Off: 39.2°F (4°C)
operating tem-
On: 24.8°F (-4°C)
19
perature setting
Off: 28.4°F (-2°C)
On: 15.8°F (-9°C)
Off: 19.4°F (-7°C)
Normal mode: operating temperature changes according to the operating conditions.
Switching
Batch stop
between batch
stop or emergency
Emergency stop
stop (*1)
This mode selects the pattern of the stop function to be operated by the external input
terminal (CN134).
20
• Batch stop: The stop of all indoor units connected to same refrigerant system due to
input signal coming from CN134.
• Emergency stop: When emergency stop is actuated, the indoor unit does not accept
the operation command from the remote controller. On the other hand, when the emer-
gency stop is released (no input from CN134), the air conditioner does not return to the
original operation until the indoor unit is turned on by the remote controller.
Priority given to the first
command
Operation mode
Priority given to external input
selecting method
of outdoor unit
(*1)
Priority given to administrative
indoor unit
21
Select the priority setting of the operation mode.
• Priority given to the first command: Priority is given to the operation mode which is set first.
• Priority given to external input of outdoor unit: Priority is given to the operation mode
which is set by the external input terminal (CN132).
• Priority given to administrative indoor unit: Priority is given to the operation mode of the
administrative indoor unit which is set by the wired remote controller.
22
Prohibited (Factory default)
23
Prohibited (Factory default)
Standard
High static pres-
24
High static pressure 1
sure mode
(equivalent to 25 Pa)
25
Prohibited (Factory default)
26
Prohibited (Factory default)
27
Prohibited (Factory default)
Celsius (°C)
Change of unit
28
(Temperature)
Fahrenheit (°F)
Mpa
Change of unit
29
(Pressure)
psi
Level 1 (stop)
Level 2
(operated at 40% capacity)
Level 3
Energy saving
(operated at 60% capacity)
level setting (*1)
Level 4
30
(operated at 80% capacity)
Level 5
(operated at 100% capacity)
The capacity limit can be selected by the external input terminal (CN133) when operat-
ing with the "Energy Saving Peak Cut function".
The lower the level, the more the effect of energy saving, but the cooling/heating perfor-
mance will also drop.
31
Prohibited (Factory default)
34
Prohibited (Factory default)
Presence of
Invalid
heater selection
control using
outdoor tempera-
Valid
35
ture (*1)
If "Heater selection control 1 or 2 using outdoor temperature" is used for any of the
indoor units of the refrigerant system, select "Valid". For more details on settings for this
item, see the Design & Technical manual.
0
0
0
1
1
2
0
2
0
3
1
3
0
0
1
4
0
0
1
6
0
0
0
0
0
1
1
7
0
2
0
3
0
4
1
8
0
0
0
0
0
1
1
9
0
2
0
3
0
0
2
0
0
1
0
0
2
1
0
1
0
2
2
2
0
0
2
3
0
0
0
0
2
4
0
1
2
5
0
0
2
6
0
0
2
7
0
0
0
0
2
8
0
1
0
0
2
9
0
1
0
0
0
1
0
2
3
0
0
3
0
4
3
1
0
0
3
4
0
0
0
0
3
5
0
1
-4.0°F (-20°C)
-0.4°F (-18°C)
3.2°F (-16°C)
Outdoor tempera-
6.8°F (-14°C)
ture zone bound-
10.4°F (-12°C)
ary temperature
36
14.0°F (-10°C)
A (*1)
17.6°F (-8°C)
21.2°F (-6°C)
24.8°F (-4°C)
For more details on settings for this item, see the Design & Technical manual.
42.8°F (6°C)
14.0°F (-10°C)
17.6°F (-8°C)
21.2°F (-6°C)
24.8°F (-4°C)
28.4°F (-2°C)
32.0°F (0°C)
Outdoor tempera-
35.6°F (2°C)
ture zone bound-
ary temperature
37
39.2°F (4°C)
B (*1)
42.8°F (6°C)
46.4°F (8°C)
50.0°F (10°C)
53.6°F (12°C)
57.2°F (14°C)
60.8°F (16°C)
64.4°F (18°C)
For more details on settings for this item, see the Design & Technical manual.
Capacity prior-
Off (quiet priority)
ity setting (in low
On (capacity priority)
noise mode) (*1)
40
If the cooling/heating performance becomes insufficient when the low noise mode is
set, it is possible to set "capacity priority" that automatically cancels the low noise mode
(once performance is restored, the mode will automatically return to the low noise
mode).
Off (Normal)
Low noise mode
41
setting (*1)
On (Low noise mode)
42
Prohibited (Factory default)
Normal mode
Maximum circuit
20 A
breaker setting
55
30 A
For more details on settings for this item, see the Design & Technical manual.
60
Prohibited (Factory default)
61
Prohibited (Factory default)
Setting number (x00)
Setting number (x01)
Electricity meter
······
No. setting 1 (*2)
70
Setting number (x98)
Setting number (x99)
Set the ones digit and tens digit of the No. of the electricity meter connected to CN135.
Setting number (0xx)
Electricity meter
Setting number (1xx)
No. setting 2 (*2)
71
Setting number (2xx)
Set the hundreds digit of the No. of the electricity meter connected to CN135.
Setting number (xx00)
Setting number (xx01)
Electricity meter
pulse setting
······
1 (*3)
72
Setting number (xx98)
Setting number (xx99)
Set the ones digit and tens digit of the No. of the electricity meter pulse setting con-
nected to CN135.
Setting number (00xx)
Setting number (01xx)
Electricity meter
pulse setting
······
2 (*3)
73
Setting number (98xx)
Setting number (99xx)
Set the hundreds digit and thousands digit of the electricity meter pulse setting con-
nected to CN135.
90
Prohibited (Factory default)
92
Prohibited (Factory default)
96
Prohibited (Factory default)
*1: Do not set this for outdoor units with Slave setting.
*2: When electricity meter No. is set to "000" and "201 to 299", the pulses input to
CN135 become ineffective. Available setting number is "001" to "200"
*3: When the electricity meter pulse setting is set to "0000", the pulses input to CN135
become ineffective. Available setting number is "0001" to "9999"
0
0
0
1
0
2
0
3
3
6
0
4
0
5
0
6
0
7
0
8
0
0
0
1
0
2
0
3
0
4
0
5
0
6
0
7
3
7
0
8
0
9
1
0
1
1
1
2
1
3
1
4
1
5
0
0
4
0
0
1
0
0
4
1
0
1
4
2
0
0
0
0
5
5
0
1
0
2
6
0
0
0
6
1
0
0
0
0
0
1
7
0
···
···
9
8
9
9
0
0
7
1
0
1
0
2
0
0
0
1
7
2
···
···
9
8
9
9
0
0
0
1
7
3
···
···
9
8
9
9
9
0
0
0
9
2
0
0
9
6
0
0
En-12