STRUCTURE, FUNCTION AND MAINTENANCE STANDARD
Operation
When solenoid is de-energized
When the signal current does not flow from the
PPC lock switch or swing lock switch, solenoid
(3) is de-energized.
For this reason, spool (5) is pushed fully to the
left by spring (6).
As a result, the circuit between ports P and A
closes and the pressurized oil from the control
pump does not flow to the actuator.
At the same time, the pressurized oil from the
actuator flows from port A to port T, and is then
drained to the tank.
When solenoid is energized
When the signal current flows from the PPC lock
switch or swing lock switch to solenoid (3), sole-
noid (3) is energized.
For this reason, spool (5) is pushed to the right
in the direction of the arrow.
As a result, the pressurized oil from the control
pump flows from port P through the inside of
spool (5) to port A, and then flows to the actua-
tor. At the same time, port T is closed, and this
stops the oil from flowing to the tank.
10-116
SOLENOID VALVE
1. Connector
2. Movable core
3. Coil
4. Cage
5. Spool
6. Block
7. Spring
PC600, 600LC-7