Connect The Gas Line (For Gas Models) - Crosley CFDMHE8105AW User's Manual & Installation Instructions

Table of Contents

Advertisement

CONNECT THE GAS LINE (FOR GAS MODELS)

Review the "Gas Requirements" section on page 15. Remove the pipe
thread protective cap.
Apply a pipe joint compound or about 11/2" wraps of teflon tape over all
threaded connections.
The pipe joint compound must be resistant to the actions of any
liquefied petroleum gas.
Connect the gas supply to your dryer. An additional fitting is required
to connect the
3/8
the
" (1 cm) male threaded end on the dryer. Use only new AGA or CSA
certified gas supply line with SS flexible connectors. within 6 ft (1.8 m) of
the dryer
Securely tighten the gas line fitting over the threads.
Turn on the gas supply.
Manual
Shutoff
Valve
Open
WARNING
All gas installations of the dryer must be equipped with Manual Shut-
Off valve.
Uncoated copper tubing will corrode when subjected to natural gas,
causing gas leaks. Use ONLY black iron, stainless steel, or plastic-
coated brass piping for gas supply.
Check all gas connections for leaks using a soap solution.
If bubbles appear, tighten the connections and recheck. DO NOT use
an open flame to check for gas leaks.
24
3/4
" (1.9 cm) female thread end of a flexible connector to
Flare
GAS FLOW
Union
Nipple
Flexible
Connector
All connections must be wrench-tightened
Flare
Union
Inlet Pipe on
Back of Dryer