Control Panel Error Codes - Meridian 4055 SEED EXPRESS Operator's Manual

Bulk seed tender
Table of Contents

Advertisement

Operator's Manual: 4055 Seed Express

4.3.11 Control Panel Error Codes:

Fig 55 - Control panel
ERROR CODE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
4-12
Bulk Seed Tender
a
b
Table 1 - Control Panel Display Error Codes
CAUSE
RF Communication
Wrong ID
Scale Bar Fault
Low Battery
Conveyor Speed Fault
Engine Start Fault
Engine Stop Fault
Conveyor Lift Fault
Conveyor Lower Fault
Conveyor Left Fault
Conveyor Right Fault
Slide Gate 1 Open Fault
Slide Gate 1 Close Fault
Slide Gate 2 Open Fault
Slide Gate 2 Close Fault
Error codes are invalid during manual operation.
®
Error Code Outputs:
The receiver module can identify problems with
the system in the form of an error code. Check
red indicator light (a) on the receiver to diagnose
system problems.
Each of the outputs from the receiver module is
designed with built-in short circuit and overload
protection. The outputs can also detect a no-
-load or broken wire condition.
These error conditions are indicated by the red
LED indicator on the receiver module or the
HISTOGRAM page on the optional Palm Pilot™.
Refer to the Error Code Chart for explanation
of the error codes. Green LED indicator light
(b) will blink on the receiver during normal
communication.
The ON/OFF outputs will indicate an error under
no load or broken wire status if NOT activated,
and will detect a short if activated.
SOLUTION
Transmitter is OFF.
Transmitter went into sleep mode.
Interference in RF communication link.
Transmitter and receiver are not synchronized.
RS-232 communication cable between scale unit and receiver is
damaged, disconnected, or the scale unit is OFF.
System voltage is below 10.5 Volts.
Check for short or open circuit.
Check for short or open circuit.
Check for short or open circuit.
Check for short or open circuit.
Check for short or open circuit.
Check for short or open circuit.
Check for short or open circuit.
Check for short or open circuit.
Check for short or open circuit.
Check for short or open circuit.
Check for short or open circuit.
Note:
®
11.2022

Advertisement

Table of Contents
loading

Table of Contents