Maintenance Chart - DeWalt DXCM301 Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

Shut-down (Fig. 2)
1. Move Auto/Off switch to the OFF (O) position.
NOTE: If finished using compressor, follow Steps 2 - 6.
2. Turn the regulator knob counterclockwise until fully closed.
Ensure regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
4. Drain the air tank, see Draining Air Tank under Maintenance.
Ensure air tank pressure gauge reads 0 PSI (0 kPa).
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing
area.
7. Unplug air compressor and wrap the power cord loosely around
the handle.
MAINTENANCE

Maintenance Chart

Procedure
Check safety valve
Inspect air filter
Drain air tank
Check pump oil level
Change pump oil
Oil leak inspection
Inspect drive belt
Check drive belt tension
Check pulley/flywheel alignment
Check for unusual noise/vibration
Check for air leaks
Clean compressor exterior
Remove tank from service
* To check for air leaks apply a solution of soapy water around joints.
While compressor is pumping to pressure and after pressure cuts out,
look for air bubbles to form.
** The pump oil must be changed after the first 20 hours of operation.
synth
Thereafter, when using
oil, change oil every 100 hours of operation or once a year, whichever
comes first.
+ Perform more frequent in dusty or humid conditions.
++
For more information, call 1-888-895-4549 .
16
X
X +
X
X
** +
X
X
X
X
X
X
X*
X
etic blend non-detergent air compressor
X ++

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents