Adjustment Section - Pages 28 - 30 Travel Limit Adjustments - Craftsman 139.53675SRT Owner's Manual

1/2 hp for residential use only
Table of Contents

Advertisement

Adjustment
Section:
Pages 28 -30
Adjustment
Step 1
Adjust
the UP and DOWN Limits
Do not make any limit adjustments
until the
safety reversing
sensors are completely
installed_
Limit adjustment settings regulate the points at
which the door will stop when moving up or down.
The door will stop in the up direction if anything
interferes with door travel The door will reverse in
the down direction if anything interferes with the
door travel (including binding or unbalanced doors).
To operate the opener, press the Door Control push
button,. Run the opener through a complete travel
cycle.
• Does the door open and close completely?
• Does the door stay closed and not reverse
unintentionally
when fully closed?
If your door passes both of these tests, no limit
adjustments
are necessary unless the reversing test
fails (See page 30).
Adjustment
procedures are outlined below. Run
the opener through a complete travel cycle after
each adjustment.
Repeated operation of the opener during
adjustment
procedures may cause the motor to
overheat and shut off. Simply wait 15 minutes
and try again.
Read the procedures carefully before proceeding to
Adjustment Step 2o Use a screwdriver to make limit
adjustments.
Improper
adjustment
of the travel limits will
interfere
wlth
the proper
operation
of the
safety reverse
system.
The door might
not
reverse
properly
when
required
and could
seriously
injure or kill someone
under it. Test
the
safety
reverse
system
following
all
adjustments
to the travel limits. See page 30.
=,=
= =m,=
CQvaf
d
ProtecSon
Bdt
i0o
.... °I1
13mit Adjustment
Screws
Adjustment
Label
How and When to Adjust the Limits
• If the door does not open completely,
but
opens at/eastfive
feet."
Increase up travel. Turn the UP limit adjustment
screw clockwise. One hJm equals 2" of travel.
NOTE; To prevent
the trolley from hitting
the
cover protection
bolt, keep a minimum
distance
of 2-4" between
the trolley and the boil
• If door does not open at least 5 feet:
Adjust the UP (open) force as explained in
Adjustment Step 2_
• If the door does not close completely:
increase down travel Turn the DOWN limit
adjustment screw counterclockwise_ One turn
equals 2" of travel
If the door still won't close completely and the trolley
bumps into the pulley bracket (see page 4 or 5), try
lengthening the door arm, (see page 26)._
If you have adjusted the door arm to the maximum
length and the door still will not ctose completely,
lower the header bracket. See Installation Step 1,
pages 12 and 13.
o If the opener reverses in fully closed position:
Decrease down travel. Turn the DOWN limit
adjustment screw clockwise. One turn equals 2" of
travel.
• If the door reverses when closing and there is
no visible interference
to trevel cycle:
If the opener lights are flashing, the Safety Reversing
Sensors are either not installed, misaligned, or
obstructed. See Troubleshooting,
page 23.
Test the door for binding: Pull the manual release
handle. Manually open and close the door. tf the door
is binding, call for garage door service. If the door is
not binding or unbalanced, adjust the DOWN (close)
force. See Adjustment Step 2.