Honeywell SmartLine STT850 Quick Start Manual page 7

Temperature transmitter
Hide thumbs Also See for SmartLine STT850:
Table of Contents

Advertisement

Flameproof, Sira 14ATEX2046X:
II 2 GD
Ex db IIC T6..T5 Gb
o
Ex tb IIIC T 95
C Db
Intrinsically Safe, Sira
14ATEX2046X:
II 1 GD
Ex ia IIC T4 Ga
o
Ex ia IIIC T 95
C Da
FISCO Field Device (Only for FF
Option)
Ex ia IIC T4 Ga
C/
Enclosure: IP66/ IP67
ATEX
Standards: EN IEC 60079-0:2018; EN 60079-1:2014; EN 60079-11:2012; EN 60079-
31:2014
Increase Safety/ Intrinsically
Safe, Sira 14ATEX4052X:
II 3 G
Ex ec IIC T4 Gc
Ex ic IIC T4 Gc
FISCO Field Device (Only for FF
Option)
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67
Standards:
EN IEC 60079-0:2018; EN 60079-7:2015; EN 60079-11:2012
Flameproof, CSAE 22UKEX1035X
II 2 GD
Ex db IIC T6..T5 Gb
o
Ex tb IIIC T 95
C Db
Intrinsically Safe, CSAE
22UKEX1035X
II 1 GD
Ex ia IIC T4 Ga
o
Ex ia IIIC T 95
C Da
FISCO Field Device (Only for FF
Option)
C/
Ex ia IIC T4 Ga
UKCA
Increase Safety/ Intrinsic Safety:
CSAE 22UKEX1009X
II 3 G
Ex ec IIC T4 Gc
Ex ic IIC T4 Gc
FISCO Field Device (Only for FF
Option)
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67
Standards:
EN IEC 60079-0:2018; EN 60079-1:2014; EN 60079-11:2012; EN 60079-31:2014
Non Sparking:
Ex ec IIC T4 Gc
Ex ic IIC T4 Gc
FISCO Field Device (Only for FF
Option)
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67
Flameproof:
Ex d IIC T6..T5 Gb
o
Ex tD A21 IP66/IP67 T95
C
Intrinsically Safe:
Ex ia IIC T4 Ga
o
Ex ia 20 T95
C
G/ NEPSI
(CHINA)
FISCO Field Device (Only for FF
Option)
Ex ia IIC T4 Ga
Non Sparking/ Intrinsic Safety:
Ex nA IIC T4
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67
H/ KOSHA
Flameproof:
(KOREA)
Ex d IIC T4 Gb
o
Ex tD A21 T 95
C IP 66/ IP67
Intrinsically Safe:
Ex ia IIC T4
FISCO Field Device (Only for FF
Option)
Ex ia IIC T4
Enclosure: IP66/ IP67
J/ EAC Ex
Flameproof:
(Russia,
1 Ex d IIC T4 Gb
o
Belarus
Ex tb IIIC T95
C Db
and
Intrinsically Safe:
Kazakhsta
0 Ex ia IIC T4 Ga
n)
Ex ia IIIC T4 Db
FISCO Field Device (Only for FF
Option)
0 Ex ia IIC T4 Ga
Non Sparking:
2 Ex nAc IIC T4
Enclosure: IP66/ IP67
o
T 95
C ,T5: Ta=
o
o
4-20 mA/
-50
C to 85
C
Note 1
o
DE/HART/FF
T6: Ta= -50
C to
o
65
C
o
o
-50
C to 70
C
4-20 mA/
Note 2
DE/HART/FF
FISCO:
o
o
-50
C to 45
C
ALL
ALL
ALL
o
o
4-20 mA/
Note 1
-50
C to 85
C
DE/HART
"ic" Note
FISCO:
o
o
FF
2
-50
C to 45
C
ALL
ALL
ALL
o
T 95
C ,T5: Ta=
o
o
4-20 mA/
-50
C to 85
C
Note 1
o
DE/HART/FF
T6: Ta= -50
C to
o
65
C
o
o
-50
C to 70
C
4-20 mA/
Note 2
FISCO:
DE/HART/ FF
o
o
-50
C to 45
C
o
o
-50
C to 85
C
4-20 mA/
Note 1
FISCO:
DE/HART/ FF
"ic" Note 2
o
o
-50
C to 45
C
ALL
ALL
ALL
o
o
-50
C to 85
C
4-20 mA/
DE/HART/
Note 1
FISCO:
FF
o
o
-50
C to 45
C
ALL
ALL
ALL
o
T 95
C,T5: Ta= -
4-20 mA/
o
o
50
C to 85
C
DE/HART/
Note 1
o
T6: Ta= -50
C to
FF
o
65
C
o
o
4-20 mA/
-50
C to 70
C
DE/HART/
Note 2
FISCO:
o
o
FF
-50
C to 45
C
4-20 mA/
o
o
DE/HART/
Note 1
-50
C to 85
C
FF
ALL
ALL
ALL
4-20 mA/
o
o
Note 1
-50
C to 85
C
DE/HART/FF
o
o
-50
C to 70
C
4-20 mA/
Note 2
DE/HART/FF
FISCO:
o
o
-50
C to 45
C
ALL
ALL
ALL
4-20 mA/
o
o
Note 1
-50
C to 85
C
DE/HART/FF
o
o
-50
C to 70
C
4-20 mA/
Note 2
FISCO:
DE/HART/FF
o
o
-50
C to 45
C
4-20 mA/
o
o
Note 1
-50
C to 85
C
DE/HART/FF
ALL
ALL
ALL
STT850/750 Quick Start Guide
Flameproof, SIR 14.0020X
Ex db IIC T6..T5 Gb
o
Ex tb IIIC T 95
C Db
Intrinsically Safe, SIR 14.0020X
Ex ia IIC T4 Ga
Ex ia IIIC T4 Da
FISCO Field Device (Only for FF
Option)
Ex ia IIC T4 Ga
D/
Increase Safety/ Intrinsic
IECEx
Safety: SIR 14.0020X
Ex ec IIC T4 Gc
Ex ic IIC T4 Gc
FISCO Field Device (Only for FF
Option)
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67
Standards:
EN IEC 60079-0:2018; IEC 60079-1:2014; IEC 60079-11:2011; IEC 60079-
31:2013; IEC 60079-7: 2015
Flameproof:
Ex db IIC T6..T5 Gb
o
Ex tb IIIC T 95
C Db
Intrinsically Safe:
Ex ia IIC T4 Ga
Ex ia IIIC T4 Da
E/
FISCO Field Device (Only for FF
SAEx
Option)
(South
Ex ia IIC T4 Ga
Africa)
Increase Safety/ Intrinsic Safety
Ex ec IIC T4 Gc
Ex ic IIC T4 Gc
FISCO Field Device (Only for FF
Option)
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67
Flameproof:
Ex db IIC T6..T5 Gb
o
Ex tb IIIC T 95
C Db
F/
Intrinsically Safe:
INMET
Ex ia IIC T4 Ga
RO
Ex ia IIIC T4 Da
FISCO Field Device (Only for FF
Option)
Ex ia IIC T4 Ga
P/ CCoE
Ex ia IIC T4 Ga
(India)
FISCO Field Device (Only
for FF Option)
Ex ia IIC T4 Ga
Ex d IIC T4 Gb
"For details of BIS certification please visit www.bis.gov.in"
BIS Certification
Notes
1.
Operating Parameters:
4-20 mA HART (Loop Terminal)
Voltage= 11.8 to 42.4 V at terminals
Current= 4-20 mA Normal (3.8 – 23 mA Faults)
DE Model (Loop Terminal)
Voltage= 15 V to 42.4 V at terminals
Current= 4-20 mA Normal (3.8 – 23 mA Faults)
FF Model (Loop Terminal)
Voltage= 9 to 32 V
2. Intrinsically Safe Entity Parameters
See Control Drawing in section A.6
IEC 61508 SIL 2 for non-redundant use and SIL 3 for redundant use
SIL 2/3
according to EXIDA and TÜV Nord Sys Tec GmbH & Co. KG under the
following standards: IEC61508-1: 2010; IEC 61508-2: 2010; IEC61508-3:
Certification
2010.
Issued by NMi Certin B.V. in accordance with WELMEC guide 8.8, OIML
MID Approval
R117.1 Edition 2007 (E), and EN 12405-1+A2 Edition 2006. Applicable to
(not STT750)
Pt100 sensor only.
MARINE TYPE
Lloyd's Register Certificate Number: 16/60011
APPROVAL
Environmental categories ENV1, ENV2, ENV3 and ENV5 as defined in
Lloyd's Register Test Specification No. 1, February 2015
A4. Marking ATEX Directive
General:
The following information is provided as part of the labeling of the transmitter:
• Name and Address of the manufacturer
• Notified Body identification: DEKRA Quality B.V., Arnhem, the Netherlands
• For complete model number, see the Model Selection Guide for the model of
Temperature Transmitter
• The serial number of the transmitter is located on the Housing data-plate. The
first two digits of the serial number identify the year (02) and the second two digits
identify the week of the year (23); for example, 0223xxxxxxxx indicates that the
product was manufactured in 2002, in the 23 rd week.
o
T 95
C ,T5: Ta=
o
4-20 mA/
-50
C to 85
Note 1
DE/HART/FF
T6: Ta= -50
o
to 65
C
o
4-20 mA/
-50
C to 70
DE/HART/
Note 2
FISCO:
o
FF
-50
C to 45
o
4-20 mA/
Note 1
-50
C to 85
DE/HART/
"ic" Note
FISCO:
o
FF
2
-50
C to 45
ALL
ALL
ALL
o
T 95
C ,T5: Ta=
4-20 mA/
o
-50
C to 85
DE/HART/F
Note 1
T6: Ta= -50
F
o
to 65
C
o
4-20 mA/
-50
C to 70
DE/HART/F
Note 2
FISCO:
o
F
-50
C to 45
o
4-20 mA/
-50
C to 85
DE/HART/F
Note 1
FISCO:
o
F
-50
C to 45
ALL
ALL
ALL
o
T 95
C ,T5: Ta=
4-20 mA/
o
Note
-50
C to 85
DE/HART/
1
T6: Ta= -50
FF
o
to 65
C
o
4-20 mA/
-50
C to 70
Note
DE/HART/
FISCO:
2
o
FF
-50
C to 45
o
-50
C to 70
4-20 mA/
Note 2
FISCO:
DE/HART/FF
o
-50
C to 45
4-20 mA/
o
Note 1
-50
C to 85
DE/HART/FF
Current= 25 mA
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartline stt750

Table of Contents