Download Print this page

Ducane LYNX 18 Quick Start Manual

Advertisement

Quick Links

Quick Start Guide
Basic Installation Steps
Whether you're an experienced installer and service technician or relatively new to the business, if
you've installed a 14 SEER single stage heat pump before, you can install the LYNX™ 18 inverter-driven
heat pump. Powered by our proprietary QuickLink™ technology, the 4HP18V is designed to make
applying the product and installing it easy. All the basic installation steps are the same and a couple
steps you should be aware of before you begin:
• You'll need select the tonnage the unit will operate in on
the control board
• You'll also need to select the operating mode – units
ship in Efficiency mode in cooling and Efficiency mode in
heating
• 3-ton units ship with a suction line filter drier installed while
5-ton models ship with a liquid line filter drier that is field
installed.
REFRIGERANT CHARGING
There is a specific charging mode to ensure the unit runs at
full capacity. The charging mode is available in both heating
and cooling operation.
• Move the jumper to charge mode for cooling. Weigh-in
is the preferred method for charging in heating, to get the
unit to run at 100% capacity in heating mode, unplug the
wire to the liquid pressure transducer
• Refer to the charging data on the unit sticker for refrigerant
amounts
5 OPERATING MODES:
COOLING:
Efficiency Mode
• Adaptive suction pressure based on outdoor
temperature - warmer coil
• Large range of compressor modulation = highest
efficiency
Normal Mode
• Set suction pressure - standard coil temperature
• Descreased modulation range,as compared to
efficiency mode
Comfort Mode
• Reduced suction pressure - colder coil
• Maximum dehumidification = longger run times at
high compressor speed
HEATING:
Efficiency Mode
Comfort Mode

Advertisement

loading

Summary of Contents for Ducane LYNX 18

  • Page 1 Quick Start Guide Basic Installation Steps Whether you’re an experienced installer and service technician or relatively new to the business, if you’ve installed a 14 SEER single stage heat pump before, you can install the LYNX™ 18 inverter-driven heat pump. Powered by our proprietary QuickLink™ technology, the 4HP18V is designed to make applying the product and installing it easy.