[All Settings] > [Input]
[SDI Mode]
Selects among the SDI signal processing modes.
([Single1], [Single2], [Single3], [Single4], [12G 2-SI(QUAD Link)], [12G Square(QUAD Link)], [SFP])
NOTE
Single 12G-SDI Signal Format: [Single1], [Single2], [Single3], [Single4], [SFP]
Quad 3G-SDI Signal Format: [12G 2-SI(QUAD Link)], [12G Square(QUAD Link)]
- Square Division: The full image is divided into four quadrants using four 3G-SDI signal format.
- 2 SI(Sample Interleave): The full image is divided into sampling data that consisting of two pixels are transferred using four 3G-SDI signal format.
- Please connect the four cables in the order of the signals. Incorrect connection does not display the screen properly.