SECO-LARM SLI ENFORCER EAP-3D1Q Manual

Access control power supply, single output

Advertisement

Quick Links

Access Control Power Supply, Single Output
Features:
Input 110~240 VAC, fused at 3.15A
 Filtered and electronically regulated output
 AC Input and DC output LED status indicators
 Adjustable output voltage to compensate for
voltage drop
AC power failure supervision relay
 Over-current fuse-protected AC input
 12/24 VDC Outputs, field selectable
 Battery failure / low battery supervision relay
 Built-in back-up battery charger (Batteries not
included)
 Automatically switch to backup battery if AC fails
EAP-3D1Q, EAP-5D1Q,
EAP-3D1MQ, EAP-5D1MQ
Manual
®
 Selectable 2.2kΩ End-of-Line (EOL) resistor for AC
failure and battery failure supervision relays
 Selectable delay timer (5sec, 5min, 5h) for AC failure
supervision relay via DIP switch
 Automatic shutdown for short-circuit protection
EAP-3D1Q/EAP-5D1Q Only
Heavy-duty steel case with removable cover for easy
access to connections
Ventilation holes to prevent heat buildup
Both have room for two 7Ah batteries (or two 12Ah
batteries for EAP-5D1Q) (Batteries not included)
Knockouts for power connections and optional cam lock
EAP-5D1Q shown

Advertisement

loading

Summary of Contents for SECO-LARM SLI ENFORCER EAP-3D1Q

  • Page 1 EAP-3D1Q, EAP-5D1Q, EAP-3D1MQ, EAP-5D1MQ Access Control Power Supply, Single Output Manual EAP-5D1Q shown Features: Input 110~240 VAC, fused at 3.15A  Selectable 2.2kΩ End-of-Line (EOL) resistor for AC failure and battery failure supervision relays  Filtered and electronically regulated output ...
  • Page 2 If an output short-circuit occurs, the motherboard will automatically shut the output down and the red LED will turn off. When the short-circuit is removed, the motherboard will automatically come back on line. SECO-LARM U.S.A., Inc.
  • Page 3 Use at least 18-gauge wires to minimize voltage drop. The thinner the wire, the greater the voltage drop. e. Keep power limited wiring separated from non-power limited wiring (AC input, battery wiring) by a minimum distance of " (7mm) and use separate knockouts in the enclosure. SECO-LARM U.S.A., Inc.
  • Page 4 IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies with all national, state, and local laws and codes. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.

This manual is also suitable for:

Sli enforcer eap-5d1qSli enforcer eap-3d1mqSli enforcer eap-5d1mq