SECTION 1 - FOREWORD Congratulations and thank you for purchasing the ACR RCL-50 LED Searchlight. The RCL-50 LED has been tested extensively to ensure it can survive the harshest environmental conditions. This assures that the products we offer stand up to the tough marine environment. With proper care and maintenance your searchlight will be in service for years to come.
SECTION 2 - GENERAL The RCL-50 LED was specially designed for mariners who require a high intensity remote controlled searchlight that can stand up to the tough marine environment. The RCL-50 LED 12/24V searchlight system contains a narrow beam searchlight that produces approximately 100,000 peak candle power using a power efficient LED module.
After the coax cable has been routed and the “F” connectors attached to the coax cable, simply screw the “F” connectors to the Master Controller and the Point Pad™. The cable and connectors are available either through ACR Electronics or other sources of electronic hardware.
Page 7
Additional Point Pads™ (up to three (3) pads) may be used with one (1) Master Controller. A standard "T" connector or RG-59 television type "splitter" is used for each additional Point Pad (see Figure 2). Limit the total length of all coax cable used to 300 feet.
Page 8
Figure 3- URP-102 Point Pad™ Functions URP-102 Point Pad Functions • Press the ON/OFF button to turn the lights ON or OFF. • Press the SPEED button to toggle between High and Low rotation speeds. • Press the Right or Left Arrows to rotate the Searchlight in that direction. •...
Page 9
Figure 4- URP-102 Point Pad™ Surface Mount Case Figure 5- URP-102 Point Pad™ Flush Mount Case...
General wiring scheme The RCL-50 LED has a unique wiring scheme. Special attention must be paid to the following chart. The Master Controller is supplied with an in-line fuse-holder on the orange power lead. Use only 5 amp fuses in this fuse-holder. See Figure 7 for the master controller wiring diagram.
Page 11
Master Controller's in-line fuse-holder. Wiring to Searchlight The RCL-50 LED searchlight is supplied with a 15 foot integral wire harness. If you must lengthen the wire harness, use the same gauge wire to minimize the voltage drop. This is especially important for the ORANGE lamp power (+) and BLUE lamp ground (-) wires.
Page 12
The URC-103 Master Controller has the unique XRCiZ™ feature. The XRCiZ™ feature routinely operates all moving parts in the searchlight to keep the motors and drive mechanism freely running. Once activated, and every 30 days thereafter, the XRCiZ™ feature wakes up and operates the searchlight. The searchlight will rotate 360...
Page 13
(Note: Wiring must be Figure 7- URC-103 Master Controller Wiring Diagram in accordance with this diagram, improper wiring will damage components)
Page 17
Product No. 9282.3 – URP-102 Point Pad™ Secondary Station Installation Kit includes: Description Quantity ACR Part Number Point Pad™, URP-102 with Surface A3-06-2230 Mount case Case, Flush Mount A1-18-1875-2 Gasket, Surface Mount A1-25-0140-1 Gasket, Flush Mount A1-25-0140-2 U Clamp A1-17-1366 Nuts, Nylon-lock A1-05-0776 Washers...
Page 19
EC DECLARATION OF CONFORMITY ACR Electronics, Inc. hereby declares under its sole responsibility that the following product is in conformity with Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on Electromagnetic Compatibility (EMC Directive).