Owner’s Manual Permanently Lubricated Tank Mounted AIR COMPRESSOR Model No. 919.727550 • Safety Guidelines • Assembly • Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts • Français CAUTION: Sold by Sears Canada, Inc., Toronto, Ont. M5B 2B8 D23122 Rev.0...
If this air compressor is used for commercial or rental purposes, the warranty will apply for ninety days (90) from the date of purchase. This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province.
SAFETY GUIDELINES - DEFINITIONS SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
RISK OF BURSTING AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY. WHAT CAN HAPPEN FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK, CAUSING RUST AND THINNING OF THE STEEL TANK.
RISK OF ELECTRICAL SHOCK WHAT CAN HAPPEN YOUR AIR COMPRESSOR IS POWERED BY ELECTRICI- TY. LIKE ANY OTHER ELECTRICALLY POWERED DEVICE, IF IT IS NOT USED PROPERLY IT MAY CAUSE ELECTRIC SHOCK. REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN RESULT IN SERIOUS INJURY OR DEATH BY ELEC- TROCUTION.
WHAT CAN HAPPEN TOUCHING EXPOSED METAL SUCH AS THE COMPRES- SOR HEAD OR OUTLET TUBES, CAN RESULT IN SERIOUS BURNS. RISK FROM MOVING PARTS WHAT CAN HAPPEN MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING.
“cut-in” pressure. Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pres-...
HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compres- sor pump and shroud are designed to allow for proper cooling.
“cut-out” pressure. Safety Valve: If the pressure switch does not shut off the air compressor at its “cut-out” pressure setting, the safety valve will protect against high pressure by “popping out” at its factory set pressure (slightly high- er than the pressure switch “cut-out”...
Serious damage may result if the following break-in instructions are not closely followed. This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the On/Auto/Off lever is in the "OFF"...
6. After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure.
Unplug or disconnect electrical supply to the air compressor. Bleed tank of pressure Allow the air compressor to cool. To Replace or Clean Check Valve 1. Release all air pressure from air tank. See “To Drain Tank” in the Maintenance section.
(such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped) Store the air compressor in a clean and dry location. 13 - ENG Water will condense in the air tank. If not drained,...
Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressd air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM Excessive tank pressure - safety valve pops off.
Page 15
Decrease amount of air usage. Check the accessory air require- ment. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor. Check and replace if required. Remove and clean, or replace.
MESURES DE SÉCURITÉ - DÉFINITIONS SÉCURITÉ ET PRÉVENTION DE PROBLÈMES D’ÉQUIPEMENT. Afin de vous aider à identifier cette information, nous avons utilisé des signes de danger plus bas. Veuillez lire attentivement ce guide en portant une attention particulière à ces sections. Indique un danger imminent qui, s'il n'est pas évité, causera de graves blessures ou la mort.
Page 22
RISQUE D’ÉCLATEMENT RÉSERVOIR D’AIR : LES CONDITIONS SUIVANTES PEUVENT AFFAIBLIR LES PAROIS DU RÉSERVOIR ET PROVOQUER UNE EXPLOSION VIOLENTE DU RÉSERVOIR QUI RISQUE DE CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES GRAVES. RISQUE LE DÉFAUT DE VIDANGER DE FAÇON APPROPRIÉE L’EAU CONDENSÉE DANS LE RÉSERVOIR RISQUE DE CAUSER LA ROUILLE ET L’AMINCISSEMENT DES PAROIS EN ACIER DU RÉSERVOIR.
Page 23
RISQUE DE CHOC ÉLECTRIQUE RISQUE VOTRE COMPRESSEUR D’AIR EST ALIMENTÉ PAR ÉLECTRICITÉ. COMME AVEC TOUS LES APPAREILS ÉLECTRIQUES, SI L’APPAREIL N’EST PAS UTILISÉ DE FAÇON APPROPRIÉE, IL PEUT CAUSER DES CHOCS ÉLECTRIQUES. TOUTE RÉPARATION EFFECTUÉE PAR UNE PERSONNE NON QUALIFIÉE PEUT ENTRAÎNER DES BLESSURES GRAVES OU LA MORT PAR ÉLECTROCUTION.
Page 24
RISQUE DE BRÛLURES RISQUE LE FAIT DE TOUCHER AUX SURFACES DE MÉTAL EXPOSÉES TELLES QUE LA TÊTE DU COMPRESSEUR OU LES TUBES DE SORTIE PEUT CAUSER DE GRAVES BRÛLURES À LA PEAU. RISQUE RELIÉ AUX PIÈCES MOBILES RISQUE LES PIÈCES MOBILES TELLES QUE LA POULIE, LE VOLANT- MOTEUR ET LA COURROIE PEUVENT ENTRAÎNER DES BLESSURES GRAVES SI ELLES ENTRENT EN CONTACT AVEC UNE PARTIE DU CORPS OU DES VÊTEMENTS.
Veuillez vous familiariser avec ces termes avant d'utiliser l'appareil. CFM: pieds cubes par minute (pi /min). SCFM: pieds cubes par minute (pi /min) standard. Une unité de mesure de débit d'air. PSIG: jauge indiquant le nombre de livres par pouce carré (lb/po ).
MONTAGE DE L'APPAREIL Emplacement du compresseur d'air Le compresseur d'air doit être situé dans un endroit propre, sec et bien aéré. Le compresseur d'air devrait être situé à une distance d'au moins 12 po (30 cm) de tout mur ou autre obstruction qui pourrait bloquer le débit d'air.
Familiarisez-vous avec votre compresseur d'air LISEZ CE GUIDE DE L'UTILISATEUR ET TOUTES LES MESURES DE SÉCURITÉ AVANT D'UTILISER CET APPAREIL. Comparez les illustrations à votre appareil pour vous familiariser avec l'emplacement des commandes et boutons de réglage. Conservez ce guide pour références ultérieures. Description du fonctionnement Familiarisez-vous avec ces commandes avant d'utiliser l'ap- pareil.
Utilisation de l'appareil Arrêt de l'appareil : Réglez le levier marche/automatique/arrêt "On/Auto/Off" à la position d'arrêt "OFF". Avant le démarrage Procédures de rodage Le compresseur d'air peut subir d'importants dom- mages si les procédures de rodage ne sont pas suivies à la lettre.
Responsabilités du client Avant chaque utilisation Vérifier la soupape de sûreté Vidanger le réservoir Vérification de la soupape de sûreté tionne pas de façon adéquate, il peut en résulter une surpression qui pourrait causer la rupture ou une explosion du réservoir d'air. Avant de démarrer le compresseur, tirez l'anneau de la soupape de sûreté...
ENTRETIEN ET RÉGLAGES Le compresseur d'air fonctionne automatiquement lorsqu'il est sous tension. En effectuant l'entretien, vous pourriez être exposé aux sources de tension, à de l'air comprimé ou aux pièces en mouvement et subir ainsi des blessures corporelles. Avant de procéder à tout entretien ou réparation, débranchez le compresseur et purgez tout l'air pressurisé.
Avant de ranger le compresseur d'air, effectuez les étapes suivantes : Revoyez la section intitulée "Entretien" des pages précédentes et exécutez l'entretien requis. Placez le levier "On/Auto/Off" à la position "OFF". Tournez le régulateur dans le sens contraire des aigu- illes d'une montre et réglez la pression de sortie à...
En effectuant des réparations au compresseur, il se peut que vous soyez exposé aux sources de tension, aux pièces mobiles ou aux sources d'air comprimé qui risquent de causer des blessures corporelles. Débranchez le compresseur et purgez l'air pressurisé du réservoir avant d'entamer toute réparation.
Page 33
PROBLÈME Cognements Le compresseur d'air ne fournit pas suff- isamment d'air pour faire fonctionner les accessoires. Le moteur ne tourne pas. Fuite d'air continue au bouton du régula- teur. Le régulateur ne ferme pas la sortie d'air. CAUSE Soupape de retenue défectueuse. Utilisation prolongée et excessive de l'air.
Single Stage Portable AIR COMPRESSOR The model number of your Sears Air Compressor can be found on the maintenance label on the top of the shroud or on the bar code label on the rear of the air tank. Keep this number handy should you require a service call or need to order repair parts.If ordering parts...