Axis P13 Series User Manual page 52

Hide thumbs Also See for P13 Series:
Table of Contents

Advertisement

AXIS P13 Network Camera Series
Specifications
Audio input
1 Tip
Unbalanced microphone (with or without electret
power) or line
Audio output
1 Tip
Channel 1, unbalanced line, mono
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (12 V DC output), the I/O connector provides the interface to:
Digital input - For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Supervised input - Enables possibility to detect tampering on a digital input.
Digital output - For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface, through an event or from the device's web interface.
Function
DC ground
DC output
Input 1
Output 1
Input 2
Output 2
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3
Digital input or Supervised input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate. To use supervised input,
install end-of-line resistors. See connection diagram for information
about how to connect the resistors.
4
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.
5
Digital input or Supervised input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate. To use supervised input,
install end-of-line resistors. See connection diagram for information
about how to connect the resistors.
6
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.
2 Ring
Electret power if selected
2 Ring
Channel 1, unbalanced line, mono
52
3 Sleeve
Ground
3 Sleeve
Ground
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA

Advertisement

Table of Contents
loading

This manual is also suitable for:

P1375P1377P1378

Table of Contents