8
|
Electrical installation
Installer reference guide
38
Method 2: Using round crimp-style terminal
1 Strip insulation from wires and slightly twist the end of each wire.
2 Install a round crimp-style terminal on the end of the wire. Place the round
crimp-style terminal on the wire up to the covered part and fasten the
terminal with the appropriate tool.
Use the following methods for installing wires:
Wire type
Single-core wire
Or
Stranded conductor wire
twisted to "solid-like"
connection
Stranded conductor wire
with round crimp-style
terminal
The earth wire between the wire retainer and the terminal must be longer than
the other wires.
Installation method
c b
A
a
a Curled wire (single-core or twisted stranded
conductor wire)
b Screw
c Flat washer
c b
B
B
a
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
1-3
AA´
c
a
a
b
c
FTXTP-M_FTXTP-N
Daikin room air conditioner
4P728168-4 – 2023.03