Download Print this page

Sony KD-55X8 G Series Service Manual page 16

Gn5ur chassis

Advertisement

Self Diagnosis Display
Format of error timestamps
YYMMDDhhmmss (in UTC)
Example:
120823132523 -> Aug 23 2012 13:25:23 UTC
* Only when time is set, an error timestamp
is saved.
Panel Operation Time clear
<7> -> <0>
Timestamps and Error Count clear
<8> -> <0>
Total Operation Time and Boot Count clear
<9> -> <0>
•Panel Operation Time is recorded every
30 min, but Total Operation Time is recorded every 1 hr.
Therefore, the panel op. time might become larger than
the total op. time.
Total Operation Time [hr] – Boot Count – Panel Operation Time [hr]
Error Item
Back
002 MAIN POWER
003 DC ALERT
Smart Core Red LED
003 AUD ERR
blinking count
003 TU DEMOD
003 AUD ERR I2C
003 TU DEMOD I2C
003 EARC ERR I2C
005 TCON ERR
005 P ID ERR
005 FRCTC I2C
005 FRCTC ERR
006 BACKLIGHT ERR
007 TEMP ERR
007 TEMP ERR I2C
00005
FY19 model (SL/SLL)
SELF CHECK
000000000000
000000000000
000000000000
000000000000
150101000018
150101000018
150101000218
150101000223
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
;
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
00414
00002
[Home]Exit [Up/Down]Scroll
Error
timestamp
for last
recorded
error
Error count
<<
000000000000
000
000000000000
000
150101000018
003
150101000105
003
000000000000
000
000000000000
000
000000000000
000
000000000000
000
000000000000
000
000000000000
000
000000000000
000
000000000000
000
000000000000
000
000000000000
000
Error
Error
timestamp
timestamp
for second
for 3rd last
last
recorded
recorded
error
error
16

Hide quick links:

Advertisement

loading