Évacuation À L'arrière Terminaison Verticale - Napoleon Ascent Linear Premium Series Installation Manual

Hide thumbs Also See for Ascent Linear Premium Series:
Table of Contents

Advertisement

Available languages

Available languages

3.7 évacuation à l'arrière terminaison verticale
Configuration d'évacuation simple.
Lorsque la configuration de l'évacuation exige plus de zéro coude de 90°, les formules suivantes s'appliquent:
Formule 1: H
< V
T
T
Formule 2: H
+ V
< 40 pieds (12,2m)
T
T
Exemple:
V
= 5 pi (1,5m)
1
V
= 6 pi (1,8m)
2
V
= 10 pi (3,1m)
3
V
= V
+ V
+ V
= 5 pi (1,5m) + 6 pi (1,8m) + 10 pi (3,1m) = 21 pi (6,4m)
T
1
2
3
H
= 8 pi (2,4m)
1
H
= 2,5 pi (0,8m)
2
H
= H
+ H
= 8 pi (2,4m) + 2,5 pi (0,8m) = 10,5 pi (3,2m)
R
1
2
H
= 0,03 (four 90° elbows - 90°)
O
= 0,03 (360° - 90°) = 8,1 pi (2,5m)
H
= H
+ H
= 10,5 pi (3,2m) + 8,1 pi (2,5m) = 18,6 pi (5,7m)
T
R
O
H
+ V
= 18,6 pi (5,7m) + 21 pi (6,4m) = 39,6 pi (12,1m)
T
T
Formule 1:
H
< V
T
T
18,6 pi (5.7m) < 21 pi (6,4m)
Formule 2:
H
+ V
T
T
39,6 pi (12,1m) < 40 pi (12,2m)
Puisque les deux formules sont respectées, cette configuration d'évacuation est acceptable.
(H
Course verticale
requise en pieds
(mètres) V
< 40 pi (12,19m)
exigences d'évacuation
) < (V
)
T
T
Consultez le graphique pour détermine la course verticale
nécessaire V
par rapport à la course horizontale requise H
T
40 (12,2)
30 (9,1)
20 (6,1)
T
10 (3,1)
3 (0,9)
0
5
(1,5)
Longueur des courses horizontales plus les déviations en
pieds (mètres) H
La section ombragée à l'intérieur des lignes représente des
valeurs acceptables pour H
90°
V
1
10
15
20
(3,1)
(4,6)
(6,1)
T
et V
T
T
90°
V
3
H
2
V
H
2
90°
1
90°
14.1
W415-4077 / B / 01.31.23