Outdoor Unit Installation

Installation Instructions – Outdoor
Unit
Step 1: Select installation location
Before installing the outdoor unit, you must
choose an appropriate location. The following
are standards that will help you choose an
appropriate location for the unit.
Proper installation locations meet the
following standards:
Meets all spatial requirements shown in
"Installation Space Requirements" (Fig. 4.1)
Good air circulation and ventilation
Firm and solid—the location can support the
unit and will not vibrate
Noise from the unit will not disturb others
Protected from prolonged periods of direct
sunlight, rain, flooding.
Additional note when using wall mounting brackets:
Please note that the rear clearance required as
shown in Fig 4.1 is not as strict when using wall
mounting brackets. Minimum rear clearance when
using wall mounting brackets is 10 cm (~4 inches).
Page 20
install unit in the following locations:
DO NOT
Near an obstacle that will block air inlets
and outlets
Near a public street, crowded areas, or
where noise from the unit will disturb others
Near animals or plants that will be harmed
by hot or cold air discharge
Near any source of combustible gas
In a location that is exposed to large
amounts of dust or receiving high winds
In a location exposed to excessive amounts
of salty air due to sea body proximity
5
When using
brackets, rear
clerance can
be as low as
10cm (4 in)
Fig. 4.1