Problem
The compressor does not
start immediately after
pressing the FastFreeze,
or after changing the tem‐
perature.
Water flows on the rear
plate of the refrigerator.
Water flows into the refrig‐
erator.
Water flows on the floor.
Temperature cannot be
set.
The temperature in the ap‐
pliance is too low/too high.
Possible cause
The water drainage plug is
not correctly positioned.
Food products are not
wrapped properly.
Temperature is set incor‐
rectly.
This is normal, no error
has occurred.
During the automatic de‐
frosting process, frost
melts on the rear plate.
The water outlet is clog‐
ged.
Food products prevent that
water flows into the water
collector.
The melting water outlet is
not connected to the evap‐
orative tray above the com‐
pressor.
The FastFreeze or Shop‐
ping function is switched
on.
The temperature regulator
is not set correctly.
The door is not closed cor‐
rectly.
The food products' temper‐
ature is too high.
Many food products are
stored at the same time.
ENGLISH
Solution
Position the water drain‐
age plug in the correct
way.
Wrap the food products
better.
Refer to "Operation" chap‐
ter.
The compressor starts af‐
ter a period of time.
This is correct.
Clean the water outlet.
Make sure that food prod‐
ucts do not touch the rear
plate.
Attach the melting water
outlet to the evaporative
tray.
Switch off FastFreeze or
Shopping manually, or wait
until the function resets au‐
tomatically to set the tem‐
perature. Refer to "Fast‐
Freeze or Shopping func‐
tion".
Set a higher/lower temper‐
ature.
Refer to "Closing the door".
Let the food products tem‐
perature decrease to room
temperature before stor‐
age.
Store less food products at
the same time.