Warning; Operating Indicators - Cobra CPI1590 Operating Instructions Manual

1500 watt power inverter
Table of Contents

Advertisement

Operating Indicators

Operation
Intro
Operation
Customer
Low Voltage
Assistance
Installation
Secondary Icons
Notice
Caution
High Voltage
16
Warranty
Low Voltage Protection – If the
DC input voltage drops below
the alarm threshold of 11.3V the
meter will flash as shown to
indicate Low Voltage Protection,
Notes
but the unit will continue to
operate. If the input voltage drops
to 10.0V or less, the inverter will
shut down to protect itself, the
meter will continue to flash as
shown, and an alarm will sound.

Warning

To restore normal operation, return
the DC input voltage to at least
12V. The inverter will automatically
return to normal operation.
High Voltage Protection – If the
DC input voltage rises above 15.0V,
the inverter will shut down to protect
itself, the meter will flash as shown
to indicate Over Voltage Protection,
and an alarm will sound.
To restore normal operation, return
the DC input voltage to less than
15V. The inverter will automatically
return to normal operation.
Operating Indicators
Operation
Intro
Operation
Customer
High Temperature
Assistance
Main Icons
Installation
Intro
Operation
Secondary Icons
Installation
Notice
Caution
Secondary Icons
Notice
Warranty
Over Temperature Protection –
If the internal inverter temperature
rises above the alarm threshold,
the meter will flash as shown, an
alarm will sound to indicate Over
Notes
Temperature Protect, and the unit
will continue to operate. If the
Customer
Warranty
Assistance
internal temperature rises to 40ºC
(104ºF), the inverter will shut down
to protect itself, the meter will
flash as shown and the alarm will
Notes
continue to sound.
Warning
NOTE Internal inverter temperature
can rise due to being operated in a
high heat environment or due to the
Caution
Warning
fan or vents being blocked during
operation (even in relatively cool
outside air).
To restore normal operation, turn
the unit Off and allow it to cool.
The inverter will automatically
return to normal operation after
it has cooled.