1
Introduction
Scope
This manual contains information for troubleshooting the Agilent 6033A/6038A 200W Autoranging Power Supply to the
component level. Wherever applicable, the service instructions given in this manual refer to pertinent information provided
in the Operation Manual. Both manuals cover Agilent Models 6033A/6038A; differences between models are described as
required.
The following information is contained in this manual.
Calibration and Verification
Contains calibration procedures for Agilent Models 6033A/6038A. Also contains verification procedures that check the
operation of the supplies to ensure they meet the specifications of Chapter 1 in the Operating Manual.
Troubleshooting
Contains troubleshooting procedures to isolate a malfunction to a defective component on the main circuit board or to a
defective assembly (front panel, power transformer, or cable assembly). Board and assembly level removal and replacement
procedures are also given in this section.
Principles of Operation
Provides block diagram level descriptions of the supply's circuits. The primary interface, secondary interface, and the power
mesh and control circuits are described. These descriptions are intended as an aid in troubleshooting.
Replaceable Parts
Provides a listing of replaceable parts for all electronic components and mechanical assemblies for Agilent Models
6033A/6038A.
Circuit Diagrams
Contains functional schematics and component location diagrams for all Agilent 6033A/6038A circuits. The names that
appear on the functional schematics also appear on the block diagrams in Chapter 2. Thus, the descriptions in Chapter 2 can
be correlated with both the block diagrams and the schematics.
Safety Considerations
This product is a Safety Class 1 instrument, which means that it is provided with a protective earth terminal. Refer to the
Safety Summary page at the beginning of this manual for a summary of general safety information. Safety information for
specific procedures is located at appropriate places in the manual.