13.3.7
mem : Memory Area ID
Format:
0mmmmmmmB
Specifies the memory area that is the object of the parameter transfer. The following are defined for
this Instrument. Instrument-specific System Exclusive messages basically correspond to the user area
only.
mem
Data Type
1
User area
13.3.8
pset : Parameter Set Number
Format:
LSB
0nnnnnnnB
MSB
0mmmmmmmB
This field is a 2-byte (LSB, MSB) value indicating the number of the parameter set (mmmmmmmnnnnnnnB,
Binary) being transferred.
13.3.9
blk Block Number
The block number is a supplementary number that specifies which block parameter is to be accessed
when there are multiple blocks (instrument parts, etc.) that include parameters with the same ID within
a single parameter set. The array structure of a block can be expressed up to 4 dimensions, and the size
of a 1-dimensional array is expressed as 14 bits.
Format:
index3 LSB
index3 MSB
index2 LSB
index2 MSB
index1 LSB
index1 MSB
index0 LSB
index0 MSB
Note: Arranged in high dimension sequence.
1-dimension array block [index0]
1-dimension array block [index0]
Value
00jjjjjjjiiiiiiiB
00lllllllkkkkkkkB
00nnnnnnnmmmmmmmB
00pppppppoooooooB
Meaning
Read/write enabled
0iiiiiiiB
0jjjjjjjB
0kkkkkkkB
0lllllllB
0mmmmmmmB
0nnnnnnnB
0oooooooB
0pppppppB
Meaning
0000H
0000H
0000H
index0
28